You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/28968
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTaniguchi, Fabio Papa-
dc.contributor.authorMartins, Antonio Sérgio-
dc.contributor.authorPadovani, Carlos Roberto-
dc.contributor.authorSilva, Marcos Augusto de Moraes-
dc.date.accessioned2014-05-20T15:13:51Z-
dc.date.accessioned2016-10-25T17:47:51Z-
dc.date.available2014-05-20T15:13:51Z-
dc.date.available2016-10-25T17:47:51Z-
dc.date.issued1999-09-01-
dc.identifierhttp://dx.doi.org/10.1590/S0102-86501999000300009-
dc.identifier.citationActa Cirúrgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 14, n. 3, p. 00-00, 1999.-
dc.identifier.issn0102-8650-
dc.identifier.urihttp://hdl.handle.net/11449/28968-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/28968-
dc.description.abstractO presente estudo teve por objetivo padronizar modelo experimental de estimulação cardíaca artificial atrial em coelhos. Foram utilizados 20 coelhos raça Norfolk-2000 de ambos os sexos com peso mínimo de 2200g. Após anestesia endovenosa com pentobarbital(30mg/Kg), foi dissecada a veia jugular externa esquerda e introduzido eletrodo EthiconÒ especialmente preparado, até átrio direito via veia cava esquerda. Foram realizadas leituras dos parâmetros elétricos(ondaP, resistência e limiar de comando) no ato cirúrgico e com 7, 14 e 21 dias denominados M1,M2, M3 e M4 respectivamente. Observamos diferença significativa em todos as variáveis analisadas entre M1 e demais momentos. Os resultados são compatíveis com o que se conhece de estimulação cardíaca artificial em outras espécies animais e no homem. O presente modelo mostrou ser viável para estudos de estimulação cardíaca artificial.pt
dc.description.abstractThe aim of the present study was to standardize an experimental model for artificial atrial heart pacing in rabbits. Twenty rabbits(Norfolk-2000, both sexes with minimum weigth of 2200g) were studied. After endovenous anesthesia with pentobarbital sodium(30mg/Kg) the external jugular vein was dissected and a pacemaker lead(Ethiconâ ) was introduced through left cava vein until the rigth atriun. The eletric parameters(P wave, resistance and threshold) were accomplished at surgical time and at 7, 14 and 21 post-operative day. These experimental moments were denominated M1, M2, M3 and M4 respectively. The statistical analisys showed significant difference between M1 and all others experimental moments. The results are compatible with the actual knowlodge of artificial heart pacing in others animal species and in human beings. The present model showed to be viable for artificial pacing studies.en
dc.language.isopor-
dc.publisherSociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia-
dc.sourceSciELO-
dc.subjectEstimulação cardíaca artificialpt
dc.subjectMarca-passo artificialpt
dc.subjectCirurgia experimentalpt
dc.subjectCardiac pacing artificialen
dc.subjectPacemaker artificialen
dc.subjectExperimental surgeryen
dc.titlePadronização de modelo experimental para estimulação elétrica artificial atrial em coelhospt
dc.title.alternativeStandadization of an experimental model for artificial atrial pacing in rabbitsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniversidade Estadual Paulista-
dc.description.affiliationUnespUniversidade Estadual Paulista-
dc.identifier.doi10.1590/S0102-86501999000300009-
dc.identifier.scieloS0102-86501999000300009-
dc.rights.accessRightsAcesso aberto-
dc.relation.ispartofActa Cirúrgica Brasileira-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.