Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/28992
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Nagao, Rincan Katsuhilo | - |
dc.contributor.author | Cataneo, Antonio José Maria | - |
dc.date.accessioned | 2014-05-20T15:13:56Z | - |
dc.date.accessioned | 2016-10-25T17:47:54Z | - |
dc.date.available | 2014-05-20T15:13:56Z | - |
dc.date.available | 2016-10-25T17:47:54Z | - |
dc.date.issued | 2005-08-01 | - |
dc.identifier | http://dx.doi.org/10.1590/S0102-86502005000400009 | - |
dc.identifier.citation | Acta Cirúrgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 20, n. 4, p. 311-316, 2005. | - |
dc.identifier.issn | 0102-8650 | - |
dc.identifier.uri | http://hdl.handle.net/11449/28992 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/28992 | - |
dc.description.abstract | OBJETIVO: Estudar no implante lobar autólogo a eficiência da anastomose brônquica simples, a perfusão pulmonar e as complicações devido a desproporção doador/receptor. MÉTODOS: Estudou-se 15 cães submetidos à pneumonectomia esquerda, e reimplante do lobo caudal. Estudou-se a perfusão pulmonar e a anastomose brônquica, respectivamente, por cintilografia e por broncografia. O sacrifício ocorreu aproximadamente 200 dias após a cirurgia para o estudo das anastomoses e medidas de volumes e pesos pulmonares. RESULTADOS: Quatro cães foram a óbito, um por deiscência precoce de anastomose brônquica, 1 com infecção e outros 2 por infarto pulmonar devido a oclusão da veia pulmonar no local da anastomose. A perfusão relativa do pulmão direito e esquerdo foram em média respectivamente 72,7% e 27,3%. A broncografia não mostrou nem estenose nem outras alterações na anastomose brônquica. No momento do sacrifício o lobo caudal ocupava totalmente a cavidade pleural sem que houvesse evidentes desvios do mediastino. CONCLUSÕES: O estudo mostrou que a sutura brônquica término-terminal desprotegida não levou a complicações anastomóticas. Não houve complicações pelo fato do lobo implantado ter ocupado somente metade da cavidade pleural. As complicações mais importantes foram o infarto pulmonar e deiscência total da parede torácica. Tanto a broncografia como a cintilografia se mostraram eficientes respectivamente, para o estudo da anastomose brônquica e da perfusão relativa do pulmão funcionante in vivo. | pt |
dc.description.abstract | PURPOSE: To study the bronchial and vascular anastomosis in the autologus lobar lung implant and show if exist complications in transplants occuping only half of pleural cavity. METHODS: We studied 15 male from 8 to 14kg. After pneumonectomy in the left chest wall we replaced the caudal lobe. In the late post operative we made bronchography and perfusion's scintigraphy and analysed the lungs after sacrified the animal. RESULTS: Four dogs died, one by early dehiscence of bronchial anastomosis, one by infection, and two by lung infarct after occlusion of lung vein in place of anastomosis. The relative perfusion of right and left lung were 72,7% and 27,3% respectively. The bronchography didn't show stenosis nor other alterations in bronchial anastomosis. After opened the thorax we saw that caudal lobe there was filled all pleural cavity without shift of the mediastinum. CONCLUSIONS: The study showed that the end to end suture without protection don't carry the complications to the anastomosis. Didn't occour complications, in the fact the replaced lobes occupated only half pleural cavity. The most important complication was pulmonary infarct and total dehiscence of the chest wall. The bronchography was efficient to study bronchial anastomosis. Scintigraphy was useful to quantify the relative pulmonary mass functioning in vivo. | en |
dc.format.extent | 311-316 | - |
dc.language.iso | por | - |
dc.publisher | Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia | - |
dc.source | SciELO | - |
dc.subject | Pneumonectomia | pt |
dc.subject | Transplante autólogo | pt |
dc.subject | Transplante de pulmão | pt |
dc.subject | Cães | pt |
dc.subject | Pneumonectomy | en |
dc.subject | Autologus transplantation | en |
dc.subject | Lung | en |
dc.subject | transplantation | en |
dc.subject | Dogs | en |
dc.title | Implante lobar autólogo pós pneumonectomia: modelo experimental em cães | pt |
dc.title.alternative | Autologous lobar lung implant after pneumonectomy: experimental model in dogs | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | UNESP Faculdade de Medicina de Botucatu | - |
dc.description.affiliationUnesp | UNESP Faculdade de Medicina de Botucatu | - |
dc.identifier.doi | 10.1590/S0102-86502005000400009 | - |
dc.identifier.scielo | S0102-86502005000400009 | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | S0102-86502005000400009.pdf | - |
dc.relation.ispartof | Acta Cirúrgica Brasileira | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.