You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/29080
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPereira, Rodrigo A. F.-
dc.contributor.authorSilva, Luis G. W. da-
dc.contributor.authorMantovani, José R. S.-
dc.date.accessioned2014-05-20T15:14:10Z-
dc.date.accessioned2016-10-25T17:48:06Z-
dc.date.available2014-05-20T15:14:10Z-
dc.date.available2016-10-25T17:48:06Z-
dc.date.issued2008-09-01-
dc.identifierhttp://dx.doi.org/10.1590/S0103-17592008000300009-
dc.identifier.citationSba: Controle & Automação Sociedade Brasileira de Automatica. Sociedade Brasileira de Automática, v. 19, n. 3, p. 337-349, 2008.-
dc.identifier.issn0103-1759-
dc.identifier.urihttp://hdl.handle.net/11449/29080-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/29080-
dc.description.abstractNeste trabalho é proposto um algoritmo baseado nas características de afundamentos de tensão para localização de faltas em alimentadores aéreos de distribuição de energia elétrica. Quando uma falta ocorre no alimentador, afundamentos de tensão propagam-se apresentando diferentes características para cada nó do alimentador. A utilização das características dos afundamentos de tensão garante a eficiência e a robustez do algoritmo, o qual fornece resultados adequados para a localização da falta. Um alimentador aéreo, real, trifásico a três fios, 13,8 kV, com 134 nós é utilizado para avaliar o algoritmo proposto. Os resultados dos testes mostram que o algoritmo fornece não somente o provável local da falta, mas também uma área contendo este local. Essas informações são extremamente úteis para as equipes de manutenção localizarem a falta e restabelecerem o fornecimento de energia elétrica.pt
dc.description.abstractIn this work, an algorithm based on the voltage sag characteristics for locating faults on overhead distribution feeders is proposed. When a fault occurs in the feeder, voltage sags propagate presenting different characteristics for each feeder node. The usage of voltage sags ensures the efficiency and robustness of the algorithm, which provides quite suitable results for fault location. An overhead, 13.8 kV, three-phase, three-wire, 134-node, real feeder is used in order to evaluate the algorithm. Test results show that the algorithm provides not only the likely faulty node, but also an area enclosing the faulty node is established. This information is extremely useful for maintenance crews to locate the fault and reestablish the power supplying.en
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.format.extent337-349-
dc.language.isopor-
dc.publisherSociedade Brasileira de Automática-
dc.sourceSciELO-
dc.subjectLocalização de faltaspt
dc.subjectafundamentos de tensãopt
dc.subjectdistribuição de energia elétricapt
dc.subjectFault locationen
dc.subjectvoltage sagsen
dc.subjectelectric power distributionen
dc.titleAlgoritmo baseado em afundamentos de tensão para localização de faltas em alimentadores de distribuição de energia elétricapt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Federal de Goiás (UFG)-
dc.description.affiliationUniversidade Estadual Paulista Departamento de Engenharia Elétrica-
dc.description.affiliationUniversidade Federal de Goiás (UFG) Escola de Engenharia e Computação-
dc.description.affiliationUnespUniversidade Estadual Paulista Departamento de Engenharia Elétrica-
dc.identifier.doi10.1590/S0103-17592008000300009-
dc.identifier.scieloS0103-17592008000300009-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0103-17592008000300009.pdf-
dc.relation.ispartofSba: Controle & Automação Sociedade Brasileira de Automatica-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.