You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/29137
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSantos, Jean Douglas Moura dos-
dc.contributor.authorOliveira, Marco Antonio de-
dc.contributor.authorSilveira, Nelson José Freitas da-
dc.contributor.authorCarvalho, Sérgio de Souza-
dc.contributor.authorOliveira, Adeno Gonçalves-
dc.date.accessioned2014-05-20T15:14:18Z-
dc.date.accessioned2016-10-25T17:48:13Z-
dc.date.available2014-05-20T15:14:18Z-
dc.date.available2016-10-25T17:48:13Z-
dc.date.issued2011-09-01-
dc.identifierhttp://dx.doi.org/10.1590/S0103-51502011000300003-
dc.identifier.citationFisioterapia em Movimento. Pontifícia Universidade Católica do Paraná (PUCPR), v. 24, n. 3, p. 389-400, 2011.-
dc.identifier.issn0103-5150-
dc.identifier.urihttp://hdl.handle.net/11449/29137-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/29137-
dc.description.abstractINTRODUÇÃO: A utilização da fotogrametria computadorizada em prol da goniometria, ou vice-versa, na prática clínica ainda necessita de fundamentações consistentes. OBJETIVOS: Os objetivos deste estudo foram: verificar a confiabilidade inter e intraexaminadores avaliadores na quantificação das medidas angulares obtidas a partir da fotogrametria computadorizada e a goniometria e determinar a confiabilidade paralela entre esses dois diferentes instrumentos de avaliação. MATERIAIS E MÉTODOS: 26 voluntários e 4 examinadores foram utilizados no estudo. A coleta foi realizada em 4 etapas sequenciais: demarcação dos pontos anatômicos de referência, mensuração e registro dos valores goniométricos, captação da imagem do voluntário com os marcadores fixados no corpo e avaliação do registro fotográfico no programa ImageJ. RESULTADOS: O goniômetro é um instrumento confiável na maioria das evidências, porém, a confiabilidade das medições depende principalmente da uniformização dos procedimentos. Considerações metodológicas relativas ao estabelecimento de confiabilidade e padronização da colocação dos marcadores se fazem necessárias, de modo a oferecer opções de avaliação ainda mais confiáveis para a prática clínica. CONCLUSÃO: Ambos os instrumentos são confiáveis e aceitáveis, porém, mais evidências ainda são necessárias para suportar a utilização desses instrumentos, pois poucos pesquisadores têm utilizado o mesmo desenho de estudo, e a comparação dos resultados entre eles muitas vezes são difíceis.pt
dc.description.abstractINTRODUCTION: The use of photogrammetry in support of goniometry or vice versa in clinical practice still requires consistent reasoning. OBJECTIVES: The objectives of this study were to verify the inter and intra-tester reliability evaluators in the quantification of angular measurements obtained from the photogrammetry and goniometry and determine the reliability parallel between these two different assessment tools. MATERIALS and METHODS: 26 volunteers and 4 examiners were used in the study. Data collection was performed in 04 sequential steps: demarcation of anatomical reference points, measurement and recording of goniometric values, image capture volunteer with the markers attached on the body and evaluation of photographic registration in the program ImageJ. RESULTS: The goniometer is a reliable instrument in most of the evidence, but the reliability of the measurements depends mainly on the standardization of procedures. Methodological considerations regarding the establishment of reliability and standardization of the placement of markers are needed in order to offer options for further evaluation reliable for clinical practice. CONCLUSION: Both instruments are reliable and acceptable, but still needed more evidence to support their use of these instruments, because few researchers have used the same study design, and comparison of results between them, are often difficult.en
dc.format.extent389-400-
dc.language.isopor-
dc.publisherPontifícia Universidade Católica do Paraná (PUC-PR)-
dc.sourceSciELO-
dc.subjectFotogrametriapt
dc.subjectArtrometria articularpt
dc.subjectReprodutibilidade dos testespt
dc.subjectPhotogrammetryen
dc.subjectArthrometry articularen
dc.subjectReproducibility of resultsen
dc.titleConfiabilidade inter e intraexaminadores nas mensurações angulares por fotogrametria digital e goniometriapt
dc.title.alternativeReliability inter and intra-tester in angular measures by photogrammetry versus goniometryen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual do Norte Fluminense-
dc.contributor.institutionUniversidade do Vale do Paraíba-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Federal de Alfenas (UNIFAL)-
dc.contributor.institutionNOVAFAPI Faculdade de Ciências Saúde e Tecnologia-
dc.description.affiliationUniversidade Estadual do Norte Fluminense-
dc.description.affiliationUniversidade do Vale do Paraíba-
dc.description.affiliationUniversidade Estadual Paulista-
dc.description.affiliationUniversidade Federal de Alfenas-
dc.description.affiliationNOVAFAPI Faculdade de Ciências Saúde e Tecnologia-
dc.description.affiliationUnespUniversidade Estadual Paulista-
dc.identifier.doi10.1590/S0103-51502011000300003-
dc.identifier.scieloS0103-51502011000300003-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0103-51502011000300003.pdf-
dc.relation.ispartofFisioterapia em Movimento-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.