You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/29173
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMachado, Marcela Aparecida Guerreiro-
dc.contributor.authorMagalhães, Maysa Sacramento de-
dc.contributor.authorCosta, Antônio Fernando Branco-
dc.date.accessioned2014-05-20T15:14:24Z-
dc.date.accessioned2016-10-25T17:48:18Z-
dc.date.available2014-05-20T15:14:24Z-
dc.date.available2016-10-25T17:48:18Z-
dc.date.issued2008-01-01-
dc.identifierhttp://dx.doi.org/10.1590/S0103-65132008000200003-
dc.identifier.citationProdução. Associação Brasileira de Engenharia de Produção, v. 18, n. 2, p. 222-239, 2008.-
dc.identifier.issn0103-6513-
dc.identifier.urihttp://hdl.handle.net/11449/29173-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/29173-
dc.description.abstractNeste artigo é proposto, para o monitoramento de processos normais bivariados, um gráfico de controle baseado nas variâncias amostrais de duas características de qualidade. Os pontos plotados no gráfico correspondem ao valor da maior variância amostral. O gráfico proposto, denominado gráfico de VMAX, tem um desempenho superior ao do gráfico da variância amostral generalizada |S| e, além disso, tem uma melhor capacidade de diagnóstico, ou seja, com ele é mais fácil identificar a variável que teve sua variabilidade alterada pela ocorrência da causa especial. Quando a amostragem dupla está em uso o gráfico proposto também tem um desempenho superior ao do gráfico de |S|, exceto em alguns casos em que o tamanho da segunda amostra é muito grande.pt
dc.description.abstractIn this paper a control chart based on sample variances from two quality characteristics for monitoring bivariate normal processes is proposed. The points plotted on the chart are the maximum of the values of these two statistics. The proposed chart (VMAX chart) detects process disturbances faster than the generalized variance |S| chart and has a better diagnostic feature, that is, with the VMAX chart it is easier to relate an out-of-control signal to the variable whose variability has moved away from its in-control state. When the double sampling scheme is used the proposed chart has also a better performance, except in a few cases in which the size of the samples at the second stage is very large.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extent222-239-
dc.language.isopor-
dc.publisherAssociação Brasileira de Engenharia de Produção-
dc.sourceSciELO-
dc.subjectGráficos de controle de VMAXpt
dc.subjectmatriz de covariânciaspt
dc.subjectprocessos bivariadospt
dc.subjectamostragem duplapt
dc.subjectVMAX control charten
dc.subjectcovariance matrixen
dc.subjectbivariate processesen
dc.subjectdouble samplingen
dc.titleGráfico de controle de VMAX para o monitoramento da matriz de covariânciaspt
dc.title.alternativeThe VMAX control chart for monitoring the covariance matrixen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionIBGE ENCE-
dc.description.affiliationUNESP FEG Departamento de Produção-
dc.description.affiliationIBGE ENCE-
dc.description.affiliationUnespUNESP FEG Departamento de Produção-
dc.identifier.doi10.1590/S0103-65132008000200003-
dc.identifier.scieloS0103-65132008000200003-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0103-65132008000200003.pdf-
dc.relation.ispartofProdução-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.