You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/30234
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPiedade, Sérgio Rocha-
dc.contributor.authorDal Fabbro, Inácio Maria-
dc.contributor.authorMischan, Martha Maria-
dc.date.accessioned2014-05-20T15:16:54Z-
dc.date.accessioned2016-10-25T17:50:50Z-
dc.date.available2014-05-20T15:16:54Z-
dc.date.available2016-10-25T17:50:50Z-
dc.date.issued2005-01-01-
dc.identifierhttp://dx.doi.org/10.1590/S1413-78522005000100007-
dc.identifier.citationActa Ortopédica Brasileira. Sociedade Brasileira de Ortopedia e Traumatologia, v. 13, n. 1, p. 28-30, 2005.-
dc.identifier.issn1413-7852-
dc.identifier.urihttp://hdl.handle.net/11449/30234-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/30234-
dc.description.abstractNa cirurgia de reconstrução do ligamento cruzado anterior do joelho, os enxertos de tendões autólogos são a principal opção como substitutos ligamentares. Entretanto, uma das razões da falha da reconstrução ligamentar com tecidos moles é o estiramento ou elongamento do enxerto com o tempo. Neste trabalho, foram ensaiados oito tendões do músculo grácil e oito do músculo semitendinoso humanos, obtidos de quatro cadáveres do sexo masculino, com idade média de 24,5 anos. Cada tendão foi submetido a uma deformação relativa constante de 2,5% durante 600 s, com registro contínuo do relaxamento de força. A seguir, o tendão retornava ao seu comprimento inicial e era mantido num período de repouso de 300 s. Após este intervalo, um segundo ensaio, semelhante ao primeiro, era realizado. A velocidade de carregamento empregada foi de 10% do comprimento inicial do corpo de prova por segundo. Foram obtidos valores de força inicial, com 300 s e 600 s nos dois ensaios. A análise estatística sugere um comportamento mecânico mais uniforme para o tendão do músculo semitendinoso quando comparado ao tendão do músculo grácil.pt
dc.description.abstractIn the anterior cruciate ligament knee surgery reconstruction, autologous tendons graft remains as a main option as substitutive ligaments. However time effect on graft elongation is the main reason of ligament reconstruction failure. Traction tests have been performed on eight gracilis as well as on eight semitendinosus human muscles tendons obtained from four male cadavers at an average of 24.5 years. Each tendon specimen has been submitted to a deformation of 2.5% of its initial length for a time interval of 600 s with continuous recording of the corresponding force relaxation. The tendon specimen was then kept at rest for 300 s as soon as it returned to its initial length. The same specimen was then submitted to a similar test. Deformation rate for both tests was 10% of its initial length per second. Initial force values were obtained for resting time interval of 300 s as well as for 600 s. Statistical analysis suggests that the semitendinosus muscle tendon exhibits a more uniform mechanical behavior, as compared to gracilis muscle.en
dc.format.extent28-30-
dc.language.isopor-
dc.publisherSociedade Brasileira de Ortopedia e Traumatologia-
dc.sourceSciELO-
dc.subjectLigamento cruzado anteriorpt
dc.subjectJoelhopt
dc.subjectAnterior cruciate ligamenten
dc.subjectKneeen
dc.titleElongamento do enxerto de tendões do músculo grácial e semitendinoso humanos: estudo realizado em cadáveres de adultos jovenspt
dc.title.alternativeGraft semitendinosus and gracilis human muscle tendons elongation: a study carried out on young adult human cadaversen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniversidade Estadual de Campinas Faculdade de Ciências Médicas-
dc.description.affiliationUniversidade Estadual de Campinas Faculdade de Engenharia Agrícola-
dc.description.affiliationUniversidade Estadual Paulista Departamento de Bioestatística-
dc.description.affiliationUnespUniversidade Estadual Paulista Departamento de Bioestatística-
dc.identifier.doi10.1590/S1413-78522005000100007-
dc.identifier.scieloS1413-78522005000100007-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS1413-78522005000100007.pdf-
dc.relation.ispartofActa Ortopédica Brasileira-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.