Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/31450
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ribeiro, PRS | - |
dc.contributor.author | Neto, JAG | - |
dc.contributor.author | Pezza, Leonardo | - |
dc.contributor.author | Pezza, Helena Redigolo | - |
dc.date.accessioned | 2014-05-20T15:20:06Z | - |
dc.date.accessioned | 2016-10-25T17:53:08Z | - |
dc.date.available | 2014-05-20T15:20:06Z | - |
dc.date.available | 2016-10-25T17:53:08Z | - |
dc.date.issued | 2005-07-15 | - |
dc.identifier | http://dx.doi.org/10.1016/j.talanta.2005.03.001 | - |
dc.identifier.citation | Talanta. Amsterdam: Elsevier B.V., v. 67, n. 1, p. 240-244, 2005. | - |
dc.identifier.issn | 0039-9140 | - |
dc.identifier.uri | http://hdl.handle.net/11449/31450 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/31450 | - |
dc.description.abstract | A flow-injection spectrophotometric procedure is proposed for methyldopa determination in pharmaceutical preparations. The determination is based on formation of a yellow product (measured at 410 nm) after complexation of methyldopa with molybdate. Under optimal conditions, Beer's law is obeyed in a concentration range of 50-200 mg l(-1) methyldopa. Typical correlation between absorbance and analyte concentration was 0.9999. Usual excipients used as additives in pharmaceuticals do not interfere with the proposed method. The analytical frequency was 210 h(-1) and the relative standard deviation (R.S.D.) was <= 2% for sample solution containing 150 mg l(-1) methyldopa (n = 11). The analytical results obtained in commercial formulations by applying the proposed FIA method were in good agreement with labeled values and those obtained by the Brazilian Pharmacopoeia procedure at 95% confidence level. (C) 2005 Elsevier B.V. All rights reserved. | en |
dc.format.extent | 240-244 | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier B.V. | - |
dc.source | Web of Science | - |
dc.subject | flow-injection analysis | pt |
dc.subject | methyldopa | pt |
dc.subject | molybdate | pt |
dc.subject | pharmaceutical formulations | pt |
dc.title | Flow-injection spectrophotometric determination of methyldopa in pharmaceutical formulations | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | UNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil | - |
dc.description.affiliationUnesp | UNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil | - |
dc.identifier.doi | 10.1016/j.talanta.2005.03.001 | - |
dc.identifier.wos | WOS:000230528500032 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Talanta | - |
dc.identifier.orcid | 0000-0003-0197-7369 | pt |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.