You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/31662
Full metadata record
DC FieldValueLanguage
dc.contributor.authorde Oliveira, A. P.-
dc.contributor.authorNeto, JAG-
dc.contributor.authorNobrega, J. A.-
dc.contributor.authorOliveira, P. V.-
dc.date.accessioned2014-05-20T15:20:20Z-
dc.date.accessioned2016-10-25T17:53:27Z-
dc.date.available2014-05-20T15:20:20Z-
dc.date.available2016-10-25T17:53:27Z-
dc.date.issued2005-07-01-
dc.identifier.citationAtomic Spectroscopy. Shelton: Perkin-elmer Corp, v. 26, n. 4, p. 158-161, 2005.-
dc.identifier.issn0195-5373-
dc.identifier.urihttp://hdl.handle.net/11449/31662-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/31662-
dc.description.abstractA method for the direct determination of Ni in soft drinks by graphite furnace atomic absorption spectrometry using a transversely heated graphite atomizer (THGA), Zeeman-effect background corrector, and Co as the internal standard (IS) is proposed. Magnesium nitrate was used to stabilize both Ni and Co. All diluted samples (1+1) in 0.2% (v/v) HNO3 and reference solutions [5.0-50 mu g L-1 Ni in 0.2% (v/v) HNO3] were spiked with 50 mu g L-1 Co. For a 20-mu L sample dispensed into the atomizer, correlations between the ratio of absorbance of Ni to absorbance of Co and the analyte concentration were close to 0.9996. The relative standard deviation of the measurements varied from 0.5 to 3.4% and 1.0 to 7.0% (n=12) with and without IS, respectively. Recoveries within 98-104% for Ni spikes were obtained using IS. The characteristic mass was calculated as 43 pg Ni and the limit of detection was 1.4 mu g L-1. The accuracy of the method was checked for the direct determination of Ni in soft drinks and the results obtained with IS were better than those without IS.en
dc.format.extent158-161-
dc.language.isoeng-
dc.publisherPerkin-elmer Corp-
dc.sourceWeb of Science-
dc.titleElectrothermal AAS determination of Ni in soft drinks using Co as the internal standarden
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.description.affiliationUniv Estadual Paulista, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUniv Fed Sao Carlos, Dept Quim, BR-13560970 Sao Carlos, SP, Brazil-
dc.description.affiliationUniv São Paulo, Inst Quim, São Paulo, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.wosWOS:000231100000005-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAtomic Spectroscopy-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.