You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/31692
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCiric, R. M.-
dc.contributor.authorOchoa, L. F.-
dc.contributor.authorPadilla-Feltrin, A.-
dc.contributor.authorNouri, H.-
dc.date.accessioned2014-05-20T15:20:23Z-
dc.date.accessioned2016-10-25T17:53:29Z-
dc.date.available2014-05-20T15:20:23Z-
dc.date.available2016-10-25T17:53:29Z-
dc.date.issued2005-11-01-
dc.identifierhttp://dx.doi.org/10.1049/ip-gtd:20045226-
dc.identifier.citationIee Proceedings-generation Transmission and Distribution. Hertford: IEE-inst Elec Eng, v. 152, n. 6, p. 977-982, 2005.-
dc.identifier.issn1350-2360-
dc.identifier.urihttp://hdl.handle.net/11449/31692-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/31692-
dc.description.abstractThe neutral wire in most existing power flow and fault analysis software is usually merged into phase wires using Kron's reduction method. In some applications, such as fault analysis, fault location, power quality studies, safety analysis, loss analysis etc., knowledge of the neutral wire and ground currents and voltages could be of particular interest. A general short-circuit analysis algorithm for three-phase four-wire distribution networks, based on the hybrid compensation method, is presented. In this novel use of the technique, the neutral wire and assumed ground conductor are explicitly represented. A generalised fault analysis method is applied to the distribution network for conditions with and without embedded generation. Results obtained from several case studies on medium- and low-voltage test networks with unbalanced loads, for isolated and multi-grounded neutral scenarios, are presented and discussed. Simulation results show the effects of neutrals and system grounding on the operation of the distribution feeders.en
dc.format.extent977-982-
dc.language.isoeng-
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)-
dc.sourceWeb of Science-
dc.titleFault analysis in four-wire distribution networksen
dc.typeoutro-
dc.contributor.institutionUniv W England-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv W England, Sch Elect & Comp Engn, Fac Comp Engn & Math Sci, Bristol BS16 1QY, Avon, England-
dc.description.affiliationUniv Estadual Paulista Julio Mesquita Filho, Fac Engn Ilha Solteira, BR-15385000 Ilha Solteira, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista Julio Mesquita Filho, Fac Engn Ilha Solteira, BR-15385000 Ilha Solteira, SP, Brazil-
dc.identifier.doi10.1049/ip-gtd:20045226-
dc.identifier.wosWOS:000233379800030-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofIEE Proceedings: Generation, Transmission and Distribution-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.