DC FieldValueLanguage
dc.contributor.authorAlves, D. A.-
dc.contributor.authorDa Silva, LCP-
dc.contributor.authorCastro, C. A.-
dc.contributor.authorDa Costa, V. F.-
dc.date.accessioned2014-05-20T15:20:44Z-
dc.date.accessioned2016-10-25T17:53:55Z-
dc.date.available2014-05-20T15:20:44Z-
dc.date.available2016-10-25T17:53:55Z-
dc.date.issued2003-12-01-
dc.identifierhttp://dx.doi.org/10.1080/15325000390248792-
dc.identifier.citationElectric Power Components and Systems. Philadelphia: Taylor & Francis Inc., v. 31, n. 12, p. 1167-1177, 2003.-
dc.identifier.issn1532-5008-
dc.identifier.urihttp://hdl.handle.net/11449/31972-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/31972-
dc.description.abstractNew parameterization schemes have been proposed by the authors in Part I of this paper. In this part these new options for the parameterization of power flow equations are tested, namely, the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, and the transmission line power losses (real and reactive). These different parameterization schemes can be used to obtain the maximum loading point without ill-conditioning problems, once the singularity of Jacobian matrix is avoided. The results obtained with the new approach for the IEEE test systems (14, 30, 57, and 118 buses) show that the characteristics of the conventional method are not only preserved but also improved. In addition, it is shown that the proposed method and the conventional one can be switched during the tracing of PV curves to determine, with few iterations, all points of the PV curve. Several tests were also carried out to compare the performance of the proposed parameterization schemes for the continuation power flow method with the use of both the secant and tangent predictors.en
dc.format.extent1167-1177-
dc.language.isoeng-
dc.publisherTaylor & Francis Inc-
dc.sourceWeb of Science-
dc.subjectcontinuation power flowpt
dc.subjectparameterization techniquespt
dc.subjectvoltage stability analysispt
dc.subjectPV curvespt
dc.subjectmaximum loading pointpt
dc.titleStudy of alternative schemes for the parameterization step of the continuation power flow method based on physical parameters, part II: Performance evaluationen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.description.affiliationPaulista State Univ, Dept Elect Engn, Fac Elect Engn, BR-15378000 Ilha Solteira, SP, Brazil-
dc.description.affiliationState Univ Campinas, Sch Elect & Comp Engn, Campinas, SP, Brazil-
dc.description.affiliationUnespPaulista State Univ, Dept Elect Engn, Fac Elect Engn, BR-15378000 Ilha Solteira, SP, Brazil-
dc.identifier.doi10.1080/15325000390248792-
dc.identifier.wosWOS:000186433600004-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofElectric Power Components and Systems-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.