Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/32270
Registro de metadados completo
Campo DCValorIdioma
dc.contributor.authorSantini, A. O.-
dc.contributor.authorOliveira, Jose Eduardo de-
dc.contributor.authorPezza, Helena Redigolo-
dc.contributor.authorPezza, Leonardo-
dc.date.accessioned2014-05-20T15:21:05Z-
dc.date.accessioned2016-10-25T17:54:22Z-
dc.date.available2014-05-20T15:21:05Z-
dc.date.available2016-10-25T17:54:22Z-
dc.date.issued2006-09-01-
dc.identifierhttp://dx.doi.org/10.1016/j.microc.2006.04.007-
dc.identifier.citationMicrochemical Journal. Amsterdam: Elsevier B.V., v. 84, n. 1-2, p. 44-49, 2006.-
dc.identifier.issn0026-265X-
dc.identifier.urihttp://hdl.handle.net/11449/32270-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/32270-
dc.description.abstractThe characteristics, performance, and application of an electrode, namely, Pt vertical bar Hg vertical bar Hg-2(IBP)(2)vertical bar Graphite, where IBP stands for ibuprofenate ion, are described. This electrode responds to IBP with sensitivity of (58.6 +/- 0.9) mV decade 1 over the range 5.0 x 10(-5)-1.0 x 10(-1) mol L-1 at pH 6.0-9.0 and a detection limit of 3.8 x 10(-5) mol L-1. The electrode is easily constructed at a relatively low cost with fast response time (within 1530 s) and can be used for a period of 5 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for ibuprofen in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used for the direct assay of ibuprofen in commercial tablets by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedure. (c) 2006 Elsevier B.V. All rights reserved.en
dc.format.extent44-49-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectibuprofenate-sensitive electrodept
dc.subjectpotentiometrypt
dc.subjecttablet formulationspt
dc.titleA new potentiometric ibuprofenate ion sensor immobilized in a graphite matrix for determination of ibuprofen in tabletsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUnespUNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.doi10.1016/j.microc.2006.04.007-
dc.identifier.wosWOS:000240428800008-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofMicrochemical Journal-
dc.identifier.orcid0000-0003-0197-7369pt
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.