DC FieldValueLanguage
dc.contributor.authorAparecida Lobo, Fabiana-
dc.contributor.authorVillafranca, Ana Cristina-
dc.contributor.authorPaiva de Oliveira, Adriana-
dc.contributor.authorde Moraes, Mercedes-
dc.date.accessioned2014-05-20T15:21:06Z-
dc.date.accessioned2016-10-25T17:54:24Z-
dc.date.available2014-05-20T15:21:06Z-
dc.date.available2016-10-25T17:54:24Z-
dc.date.issued2007-01-01-
dc.identifier.citationAtomic Spectroscopy. Shelton: Perkin-elmer Corp, v. 28, n. 1, p. 17-23, 2007.-
dc.identifier.issn0195-5373-
dc.identifier.urihttp://hdl.handle.net/11449/32286-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/32286-
dc.description.abstractThis work describes the development of an analytical procedure for on-line tin determination using thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS). Two tubes were evaluated as atomization cells: a metallic tube (Ni-Cr, principal components composition: 73.95% Ni and 16.05% Cr) and a ceramic tube (99.8% Al2O3). The use of air as the carrier was made by employing a Rheodyne valve to inject the samples, allowing an analytical frequency of 90 h(-1) and avoiding sample dispersion. The carrier flow rate (air), sample volume injected, and acid concentration (HCl) were evaluated for the optimization of the TS-FF-AAS system. The sensitivity for 50 mL of analytical solution with TS-FF-AAS was 2 and 5 times higher (to metallic and ceramic tube, respectively) than using an acetylene-nitrous oxide flame with pneumatic aspiration (requiring a sample volume of approximately 20 times higher.en
dc.format.extent17-23-
dc.language.isoeng-
dc.publisherPerkin-elmer Corp-
dc.sourceWeb of Science-
dc.titleComparison of metallic and ceramic tubes as atomization cells for tin determination by TS-FF-AASen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniv Fed Mato Grosso-
dc.description.affiliationUniv Estadual Paulista, UNESP, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUniv Fed Mato Grosso, Dept Quim, BR-78060900 Cuiaba, MT, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, UNESP, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.wosWOS:000245448700003-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAtomic Spectroscopy-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.