You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/32307
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLima Borges, Elisangela Cardoso-
dc.contributor.authorde Oliveira, Adriana Paiva-
dc.contributor.authorde Moraes, Mercedes-
dc.contributor.authorGomes Neto, Jose Anchieta-
dc.date.accessioned2014-05-20T15:21:08Z-
dc.date.accessioned2016-10-25T17:54:26Z-
dc.date.available2014-05-20T15:21:08Z-
dc.date.available2016-10-25T17:54:26Z-
dc.date.issued2006-09-01-
dc.identifier.citationAtomic Spectroscopy. Shelton: Perkin-elmer Corp, v. 27, n. 5, p. 139-145, 2006.-
dc.identifier.issn0195-5373-
dc.identifier.urihttp://hdl.handle.net/11449/32307-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/32307-
dc.description.abstractThe present paper describes the use of sugar cane bagasse as solid phase extractor for cadmium determination after complexation of the analyte with ammonium diethyldithiophosphate (ADDP) and sorption of the Cd-DDP complexes on the solid support. The concomitants were separated using a flow injection analysis (FIA) system coupled to flame atomic absorption spectrometry (FAAS) for determination. The main parameters such as ADDP concentration, acid medium, flow rate, reaction coil length, and reaction time were investigated.The results obtained with HNO3 showed good accuracy and precision. The enhancement factor was 20.5 times for a 120-second preconcentration time, and the analytical frequency was 25 determinations per hour. The calibration curve was linear over the concentration range of 1-40 mu g L-1 Cd with a LOD of 0.697 mu g L-1 Cd and a relative standard deviation of 0.96% after 12 successive measurements of 30 mu g L-1 Cd.The proposed method was evaluated for the FIA-FAAS analysis of certified reference materials (tomato leaves, spinach leaves, and bovine liver) and Cd-spiked foods (shrimp, sardine, tuna, chicken liver and bovine liver). Good recoveries (80.0-97.1%) for the Cd-spiked samples and certified reference materials were obtained. The results of bagasse-packed minicolumns were compared with Si-C,8 packed minicolumns. The F-test was applied between Si-C-18/Bagasse minicolumns, Si-C-18/certified values, and bagasse/certified values. It was found that the results were in agreement with the certified values at a 95% confidence level.en
dc.format.extent139-145-
dc.language.isoeng-
dc.publisherPerkin-elmer Corp-
dc.sourceWeb of Science-
dc.titleUse of sugar cane bagasse as solid phase extractor for cadmium determination by FAASen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Estadual Paulista, UNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, UNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.wosWOS:000242509800001-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAtomic Spectroscopy-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.