You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/32684
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSantini, A. O.-
dc.contributor.authorSilva, E. S.-
dc.contributor.authorPezza, Helena Redigolo-
dc.contributor.authorNasser, ALM-
dc.contributor.authorMelios, C. B.-
dc.contributor.authorPezza, Leonardo-
dc.date.accessioned2014-05-20T15:21:33Z-
dc.date.accessioned2016-10-25T17:55:01Z-
dc.date.available2014-05-20T15:21:33Z-
dc.date.available2016-10-25T17:55:01Z-
dc.date.issued2004-07-08-
dc.identifierhttp://dx.doi.org/10.1016/j.talanta.2003.12.039-
dc.identifier.citationTalanta. Amsterdam: Elsevier B.V., v. 63, n. 4, p. 833-838, 2004.-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://hdl.handle.net/11449/32684-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/32684-
dc.description.abstractThe characteristics, performance, and application of an electrode, namely, Pt\Hg\Hg-2(PABzt)(2)\ graphite, where PABzt stands for p-aminobenzoate ion, are described. This electrode responds to PABzt with sensivity of (58.1 +/- 1.0) mV per decade over the range 1.0 x 10(-4) to 1.0 x 10(-1) mol l(-1) at pH 6.5-8.0 and a detection limit of 3.2 x 10(-5) mol l(-1). The electrode shows easy construction, fast response time (within 10-30 s), low-cost, and excellent response stability (lifetime greater than 6 months, in continuous use). The proposed sensor displayed good selectivity for p-aminobenzoate in the presence of several substances, especially, concerning carboxylate and inorganic anions. It was used to determine p-aminobenzoate in pharmaceutical formulations by means of the standard additions method. The results obtained by using this electrode compared very favorably with those given by an HPLC procedure. (C) 2004 Elsevier B.V. All rights reserved.en
dc.format.extent833-838-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectp-aminobenzoate-sensitive electrodept
dc.subjectpotentiometrypt
dc.subjectpharmaceutical formulationspt
dc.titlep-Aminobenzoate ion determination in pharmaceutical formulations by using a potentiometric sensor immobilized in a graphite matrixen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUnespUNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.doi10.1016/j.talanta.2003.12.039-
dc.identifier.wosWOS:000222063600004-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofTalanta-
dc.identifier.orcid0000-0003-0197-7369pt
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.