You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/32929
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBergamini, Marcio F.-
dc.contributor.authorSantos, Andre L.-
dc.contributor.authorStradiotto, Nelson Ramos-
dc.contributor.authorZanoni, Maria Valnice Boldrin-
dc.date.accessioned2014-05-20T15:21:50Z-
dc.date.accessioned2016-10-25T17:55:23Z-
dc.date.available2014-05-20T15:21:50Z-
dc.date.available2016-10-25T17:55:23Z-
dc.date.issued2007-01-04-
dc.identifierhttp://dx.doi.org/10.1016/j.jpba.2006.06.001-
dc.identifier.citationJournal of Pharmaceutical and Biomedical Analysis. Oxford: Pergamon-Elsevier B.V., v. 43, n. 1, p. 315-319, 2007.-
dc.identifier.issn0731-7085-
dc.identifier.urihttp://hdl.handle.net/11449/32929-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/32929-
dc.description.abstractA rapid and simple method for procaine determination was developed by flow injection analysis (FIA) using a screen-printed carbon electrode (SPCE) as amperometric detector. The present method is based on the amine/hydroxylamine oxidation from procaine monitored at 0.80 V on SPCE in sodium acetate solution pH 6.0. Using the best experimental conditions assigned as: pH 6.0, flow rate of 3.8 mL min(-1), sample volume of 100 mu L and analytical path of 30 cm it is possible to construct a linear calibration curve from 9.0 x 10(-6) to 1.0 x 10(-4) mol L-1. The relative standard deviation for 5.0 x 10(-5) mol L-1 procaine (15 repetitions using the same electrode) is 3.2% and detection limit calculated is 6.0 x 10(-6) mol L-1. Recoveries obtained for procaine gave a mean values from 94.8 to 102.3% and an analytical frequency of 36 injections per hour was achieved. The method was successfully applied for the determination of procaine in pharmaceutical formulation without any pre-treatment, which are in good accordance with the declared values of manufacturer and an official method based on spectrophotometric analysis. (c) 2006 Elsevier B.V. All rights reserved.en
dc.format.extent315-319-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectprocainept
dc.subjectFIA amperometricpt
dc.subjectscreen-printed carbon electrodept
dc.titleFlow injection amperometric determination of procaine in pharmaceutical formulation using a screen-printed carbon electrodeen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Estadual Paulista, UNESP, Inst Quim, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, UNESP, Inst Quim, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.doi10.1016/j.jpba.2006.06.001-
dc.identifier.wosWOS:000243554900041-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Pharmaceutical and Biomedical Analysis-
dc.identifier.orcid0000-0002-2296-1393-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.