Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/32929
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bergamini, Marcio F. | - |
dc.contributor.author | Santos, Andre L. | - |
dc.contributor.author | Stradiotto, Nelson Ramos | - |
dc.contributor.author | Zanoni, Maria Valnice Boldrin | - |
dc.date.accessioned | 2014-05-20T15:21:50Z | - |
dc.date.accessioned | 2016-10-25T17:55:23Z | - |
dc.date.available | 2014-05-20T15:21:50Z | - |
dc.date.available | 2016-10-25T17:55:23Z | - |
dc.date.issued | 2007-01-04 | - |
dc.identifier | http://dx.doi.org/10.1016/j.jpba.2006.06.001 | - |
dc.identifier.citation | Journal of Pharmaceutical and Biomedical Analysis. Oxford: Pergamon-Elsevier B.V., v. 43, n. 1, p. 315-319, 2007. | - |
dc.identifier.issn | 0731-7085 | - |
dc.identifier.uri | http://hdl.handle.net/11449/32929 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/32929 | - |
dc.description.abstract | A rapid and simple method for procaine determination was developed by flow injection analysis (FIA) using a screen-printed carbon electrode (SPCE) as amperometric detector. The present method is based on the amine/hydroxylamine oxidation from procaine monitored at 0.80 V on SPCE in sodium acetate solution pH 6.0. Using the best experimental conditions assigned as: pH 6.0, flow rate of 3.8 mL min(-1), sample volume of 100 mu L and analytical path of 30 cm it is possible to construct a linear calibration curve from 9.0 x 10(-6) to 1.0 x 10(-4) mol L-1. The relative standard deviation for 5.0 x 10(-5) mol L-1 procaine (15 repetitions using the same electrode) is 3.2% and detection limit calculated is 6.0 x 10(-6) mol L-1. Recoveries obtained for procaine gave a mean values from 94.8 to 102.3% and an analytical frequency of 36 injections per hour was achieved. The method was successfully applied for the determination of procaine in pharmaceutical formulation without any pre-treatment, which are in good accordance with the declared values of manufacturer and an official method based on spectrophotometric analysis. (c) 2006 Elsevier B.V. All rights reserved. | en |
dc.format.extent | 315-319 | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier B.V. | - |
dc.source | Web of Science | - |
dc.subject | procaine | pt |
dc.subject | FIA amperometric | pt |
dc.subject | screen-printed carbon electrode | pt |
dc.title | Flow injection amperometric determination of procaine in pharmaceutical formulation using a screen-printed carbon electrode | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Univ Estadual Paulista, UNESP, Inst Quim, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista, UNESP, Inst Quim, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil | - |
dc.identifier.doi | 10.1016/j.jpba.2006.06.001 | - |
dc.identifier.wos | WOS:000243554900041 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Journal of Pharmaceutical and Biomedical Analysis | - |
dc.identifier.orcid | 0000-0002-2296-1393 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.