Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/33321
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pereira, F. C. | - |
dc.contributor.author | Zanoni, Maria Valnice Boldrin | - |
dc.contributor.author | Guaratini, CCI | - |
dc.contributor.author | Fogg, A. G. | - |
dc.date.accessioned | 2014-05-20T15:22:19Z | - |
dc.date.accessioned | 2016-10-25T17:55:59Z | - |
dc.date.available | 2014-05-20T15:22:19Z | - |
dc.date.available | 2016-10-25T17:55:59Z | - |
dc.date.issued | 2002-01-01 | - |
dc.identifier | http://dx.doi.org/10.1016/S0731-7085(01)00526-X | - |
dc.identifier.citation | Journal of Pharmaceutical and Biomedical Analysis. Oxford: Pergamon-Elsevier B.V., v. 27, n. 1-2, p. 201-208, 2002. | - |
dc.identifier.issn | 0731-7085 | - |
dc.identifier.uri | http://hdl.handle.net/11449/33321 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/33321 | - |
dc.description.abstract | Clotrimazole was shown to react at room temperature in Britton Robinson buffer pH 2 with the reactive dye Procion Red HE-3B. The product exhibited a differential pulse polarographic peak at -0.38 V, which was well separated from the peaks of the reactive dye at -0.08, -0.80 and -0.95 V, and this allowed the indirect determination of clotrimazole in the presence of excess of the reactive dye. The method has been applied satisfactorily to the determination of clotrimazole in pharmaceutical formulations, calibration graphs are rectilinear up to at least 40 mug ml(-1). The detection limit was calculated to be 2.6 mug ml(-1) (3 sigma). (C) 2002 Elsevier B.V. B.V. All rights reserved. | en |
dc.format.extent | 201-208 | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier B.V. | - |
dc.source | Web of Science | - |
dc.subject | clotrimazole | pt |
dc.subject | differential pulse polarography | pt |
dc.subject | Procion Red HE-3B dye | pt |
dc.title | Differential pulse polarographic determination of clotrimazole after derivatization with Procion Red HE-3B | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Univ Luton | - |
dc.description.affiliation | Univ Estadual Paulista, Inst Quim, Dept Quim Analit, BR-14800900 Araraquara, SP, Brazil | - |
dc.description.affiliation | Univ Luton, Res Ctr, Sensors & Cryobiol Res Grp, Luton LU1 5DU, Beds, England | - |
dc.description.affiliationUnesp | Univ Estadual Paulista, Inst Quim, Dept Quim Analit, BR-14800900 Araraquara, SP, Brazil | - |
dc.identifier.doi | 10.1016/S0731-7085(01)00526-X | - |
dc.identifier.wos | WOS:000172456000024 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Journal of Pharmaceutical and Biomedical Analysis | - |
dc.identifier.orcid | 0000-0002-2296-1393 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.