Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/33711
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ahid, F. | - |
dc.contributor.author | Andrade, M. F. | - |
dc.contributor.author | Campos, E. A. | - |
dc.contributor.author | Luscino, F. | - |
dc.contributor.author | Vaz, Luis Geraldo | - |
dc.date.accessioned | 2014-05-20T15:22:47Z | - |
dc.date.accessioned | 2016-10-25T17:56:34Z | - |
dc.date.available | 2014-05-20T15:22:47Z | - |
dc.date.available | 2016-10-25T17:56:34Z | - |
dc.date.issued | 2004-12-01 | - |
dc.identifier | http://www.amjdent.com/previousarticles.htm | - |
dc.identifier.citation | American Journal of Dentistry. Weston: Mosher & Linder, Inc., v. 17, n. 6, p. 447-450, 2004. | - |
dc.identifier.issn | 0894-8275 | - |
dc.identifier.uri | http://hdl.handle.net/11449/33711 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/33711 | - |
dc.description.abstract | Purpose: To determine the influence of different dentin treatments on the microtensile bond strengths of adhesive resins to dentin. Methods: Fifteen human molars were ground to 600-grit to obtain flat root-dentin surfaces. Five different dentin treatments were evaluated: Group 1 - 10% phosphoric acid for 30 seconds; Group 2 - 37% phosphoric acid for 15 seconds; Group 3 - air-abrasion for 10 seconds followed by 10% phosphoric acid for 30 seconds; Group 4 - air-abasion for 10 seconds followed by 37% phosphoric acid for 15 seconds. The dental adhesive (OptiBond Solo Plus) was applied according to manufacturer's instructions and followed by composite (Z100) application to provide sufficient bulk for microtensile bond testing. All samples were placed in distilled water for 24 hours at 37degreesC, thermocycled for 500 cycles in distilled water at 10degreesC and 50degreesC, and serially sliced perpendicular to the adhesive surface and subjected to tensile forces (0.5 mm/minute). Additional samples were prepared for SEM to observe the adhesive interface. Results: Group 2 exhibited significantly (P< 0.05) lower bond strength values than all other treatments. The bond strengths of the different conditions were (in MPa): Group 1: 43.0 +/- 16.1; Group 2: 29.2 +/- 8.3; Group 3: 48.1 +/- 14.2; Group 4: 41.0 +/- 9.3. The dentin treated with phosphoric acid 37% for 15 seconds showed the lowest values of microtensile bond strength. The results obtained with Groups 1, 3 and 4 were statistically similar. | en |
dc.format.extent | 447-450 | - |
dc.language.iso | eng | - |
dc.publisher | Mosher & Linder, Inc | - |
dc.source | Web of Science | - |
dc.title | Influence of different dentin etching times and concentrations and air-abrasion technique on dentin microtensile bond strength | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | FOFEB | - |
dc.description.affiliation | UNESP, Sch Dent Araraquara, Araraquara, SP, Brazil | - |
dc.description.affiliation | FOFEB, Sch Dent Barretos, Barretos, Brazil | - |
dc.description.affiliationUnesp | UNESP, Sch Dent Araraquara, Araraquara, SP, Brazil | - |
dc.identifier.wos | WOS:000226455900014 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | American Journal of Dentistry | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.