You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/34152
Full metadata record
DC FieldValueLanguage
dc.contributor.authorValandro, L. F.-
dc.contributor.authorBaldissara, P.-
dc.contributor.authorGalhano, G. A.-
dc.contributor.authorMelo, R. M.-
dc.contributor.authorMallmann, A.-
dc.contributor.authorScotti, R.-
dc.contributor.authorBottino, M. A.-
dc.date.accessioned2014-05-20T15:23:21Z-
dc.date.accessioned2016-10-25T17:57:16Z-
dc.date.available2014-05-20T15:23:21Z-
dc.date.available2016-10-25T17:57:16Z-
dc.date.issued2007-11-01-
dc.identifierhttp://dx.doi.org/10.2341/06-165-
dc.identifier.citationOperative Dentistry. Indianapolis: Operative Dentistry Inc., v. 32, n. 6, p. 579-588, 2007.-
dc.identifier.issn0361-7734-
dc.identifier.urihttp://hdl.handle.net/11449/34152-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/34152-
dc.description.abstractThis study evaluated the effect of mechanical cycling on the bond strength of fiber posts bonded to root dentin. The hypotheses examined were that bond strength is not changed after fatigue testing and bond strength does not present vast variations according to the type of fiber post. Sixty crownless, single-rooted human teeth were endodontically treated, with the space prepared at 12 mm. Thirty specimens received a quartz fiber post (Q-FRC (DT Light-Post), and the remaining 30 specimens received a glass fiber post (G-FRC) (FRC Postec Plus). All the posts were resin luted (All Bond+Duolink), and each specimen was embedded in a cylinder with epoxy resin. The specimens were divided into six groups: G1-Q-FRC+no cycling, G2- Q-FRC+20,000 cycles (load: 50N, angle of 45 degrees; frequency: 8Hz); G3- Q-FRC+2,000,000 cycles; G4- G-FRC+no cycling; G5- G-FRC+20,000 cycles; G6- GFRC+2,000,000 cycles. The specimens were cut perpendicular to their long axis, forming 2-mm thick disc-samples, which were submitted to the push-out test. ANOVA (alpha=.05) revealed that: (a) QFRC (7.1 +/- 2.2MPa) and G-FRC (6.9 +/- 2.1MPa) were statistically similar (p=0.665); (b) the no cycling groups (7.0 +/- 2.4MPa), 20,000 cycles groups (7.0 +/- 2.1MPa) and 2,000,000 cycles groups (7.0 +/- 2.0MPa) were statistically similar (p=0.996). It concluded that mechanical cycling did not affect the bond strength of two fiber posts bonded to dentin.en
dc.format.extent579-588-
dc.language.isoeng-
dc.publisherOperative Dentistry Inc-
dc.sourceWeb of Science-
dc.titleEffect of mechanical cycling on the push-out bond strength of fiber posts adhesively bonded to human root dentinen
dc.typeoutro-
dc.contributor.institutionUniversidade Federal de Sergipe (UFS)-
dc.contributor.institutionUniv Bologna-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionDev Fdn Bahia-
dc.description.affiliationUniversidade Federal de Santa Maria (UFSM), Dept Restorat Dent, Div Prosthodont, BR-97119900 Santa Maria, RS, Brazil-
dc.description.affiliationUniv Bologna, Dept Oral Sci Alma Mater Studiorum, Div Prosthodont, Bologna, Italy-
dc.description.affiliationSão Paulo State Univ, Sao Jose dos Campos Dent Sch, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, Brazil-
dc.description.affiliationDev Fdn Bahia, Sch Dent, Salvador, BA, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Sao Jose dos Campos Dent Sch, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, Brazil-
dc.identifier.doi10.2341/06-165-
dc.identifier.wosWOS:000250821600009-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofOperative Dentistry-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.