Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/34816
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ganzarolli, S. M. | - |
dc.contributor.author | Rached, R. N. | - |
dc.contributor.author | Garcia, RCMR | - |
dc.contributor.author | Del Bel Cury, A. A. | - |
dc.date.accessioned | 2014-05-20T15:24:10Z | - |
dc.date.accessioned | 2016-10-25T17:58:18Z | - |
dc.date.available | 2014-05-20T15:24:10Z | - |
dc.date.available | 2016-10-25T17:58:18Z | - |
dc.date.issued | 2002-08-01 | - |
dc.identifier | http://dx.doi.org/10.1046/j.1365-2842.2002.00886.x | - |
dc.identifier.citation | Journal of Oral Rehabilitation. Oxford: Blackwell Publishing Ltd, v. 29, n. 8, p. 787-790, 2002. | - |
dc.identifier.issn | 0305-182X | - |
dc.identifier.uri | http://hdl.handle.net/11449/34816 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/34816 | - |
dc.description.abstract | Well-fitted dentures prevent hyperplasic lesions, provide chewing efficiency and promote patient's comfort. Several factors may affect final adaptation of dentures, as the type of the acrylic resin, the flask cooling procedure and the water uptake. This investigation evaluated the effect of water storage and two different cooling procedures [bench cooling (BC) for 2 h; running water (RW) at 20 degreesC for 45 min] on the final adaptation of denture bases. A heat-cured acrylic resin (CL, Classico, Classico Artigos Odontologicos) and two microwave-cured acrylic resins [Acron MC, (AC) GC Dent. Ind. Corp.; Onda Cryl (OC), Classico Artigos Odontologicos] were used to make the bases. Adaptation was assessed by measuring the weight of an intervening layer of silicone impression material between the base and the master die. Data was submitted to ANOVA and Tukey's test (0.05). The following means were found: (BC) CL=0.72 +/- 0.03 a; AC=0.70 +/- 0.03 b; OC=0.76 +/- 0.04 c//(RW) CL= 1.00 +/- 0.11 a; AC=1.00 +/- 0.12 a; OC=0.95 +/- 0.10 a. Different labels join groups that are not statistically different (P > 0.05). Comparisons are made among groups submitted to the same cooling procedure (BC or RW). The conclusions are: interaction of type of material and cooling procedure had a statistically significant effect on the final adaptation of the denture bases (P < 0.05); water storage was not detected as a source of variance (P > 0.05) on the final adaptation. | en |
dc.format.extent | 787-790 | - |
dc.language.iso | eng | - |
dc.publisher | Blackwell Publishing | - |
dc.source | Web of Science | - |
dc.subject | cooling | pt |
dc.subject | denture | pt |
dc.subject | acrylic resin | pt |
dc.subject | microwave | pt |
dc.subject | heat and adaptation | pt |
dc.title | Effect of cooling procedure on final denture base adaptation | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Pontifícia Universidade Católica do Paraná (PUCPR) | - |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | - |
dc.description.affiliation | Univ Estadual Paulista, Sch Hlth Sci, São Paulo, Brazil | - |
dc.description.affiliation | Pontifical Catholic Univ Parana, Sch Dent, Curitiba, Parana, Brazil | - |
dc.description.affiliation | Univ Campinas, Piracicaba Dent Sch, São Paulo, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista, Sch Hlth Sci, São Paulo, Brazil | - |
dc.identifier.doi | 10.1046/j.1365-2842.2002.00886.x | - |
dc.identifier.wos | WOS:000177951200013 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Journal of Oral Rehabilitation | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.