Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/35166
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Dixon, M. J. | - |
dc.contributor.author | Taylor, P. M. | - |
dc.contributor.author | Steagall, P. V. M. | - |
dc.contributor.author | Brondani, J. T. | - |
dc.contributor.author | Luna, Stélio Pacca Loureiro | - |
dc.date.accessioned | 2014-05-20T15:24:35Z | - |
dc.date.accessioned | 2016-10-25T17:58:50Z | - |
dc.date.available | 2014-05-20T15:24:35Z | - |
dc.date.available | 2016-10-25T17:58:50Z | - |
dc.date.issued | 2007-02-01 | - |
dc.identifier | http://dx.doi.org/10.1016/j.rvsc.2006.03.010 | - |
dc.identifier.citation | Research In Veterinary Science. London: W B Saunders Co Ltd, v. 82, n. 1, p. 85-92, 2007. | - |
dc.identifier.issn | 0034-5288 | - |
dc.identifier.uri | http://hdl.handle.net/11449/35166 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/35166 | - |
dc.description.abstract | A pressure analgesiometric device was developed for unrestrained cats. Eleven cats were studied. Stimulation was via three rounded pins within a bracelet on the forearm. The pins were advanced by manual bladder inflation. Bladder pressure was measured using a strain gauge pressure transducer. The threshold was recorded at the behavioural end point. Thresholds were measured at 5 and 15 min intervals for 2-4 h, after removal/replacement of the cuff, for 120 min after SC butorphanol (0.4 mg/kg), and with mild skin inflammation at the testing site. Data were analysed using ANOVA. Pressure thresholds in untreated cats were around 150 mmHg. The minimum interval for testing was established as 15 min. Data were reproducible over 4 h and beyond 24 h. Thresholds in 5 cats increased (P < 0.05) above baseline for 45 min after butorphanol with a maximum increase of 270 +/- 182 mmHg at 10 min. Thresholds decreased with inflammation. The method appears suitable for feline analgesia investigations. (c) 2006 Elsevier Ltd. All rights reserved. | en |
dc.format.extent | 85-92 | - |
dc.language.iso | eng | - |
dc.publisher | W B Saunders Co Ltd | - |
dc.source | Web of Science | - |
dc.subject | pressure threshold | pt |
dc.subject | cat | pt |
dc.subject | analgesia | pt |
dc.subject | pain | pt |
dc.subject | equipment | pt |
dc.subject | measurement | pt |
dc.subject | pressure nociceptive threshold testing | pt |
dc.subject | opioid | pt |
dc.subject | NSAID | pt |
dc.title | Development of a pressure nociceptive threshold testing device for evaluation of analgesics in cats | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Univ Estadual Paulista Julio Mesquita Filho, FMVZ, Fac Vet Med & Anim Sci, Botucatu, SP, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista Julio Mesquita Filho, FMVZ, Fac Vet Med & Anim Sci, Botucatu, SP, Brazil | - |
dc.identifier.doi | 10.1016/j.rvsc.2006.03.010 | - |
dc.identifier.wos | WOS:000243626500016 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Research in Veterinary Science | - |
dc.identifier.orcid | 0000-0001-5312-9076 | pt |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.