Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/35219
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Milani, M. R. | - |
dc.contributor.author | Stradiotto, Nelson Ramos | - |
dc.contributor.author | Cardoso, Arnaldo Alves | - |
dc.date.accessioned | 2014-05-20T15:24:39Z | - |
dc.date.accessioned | 2016-10-25T17:58:56Z | - |
dc.date.available | 2014-05-20T15:24:39Z | - |
dc.date.available | 2016-10-25T17:58:56Z | - |
dc.date.issued | 2003-06-01 | - |
dc.identifier | http://dx.doi.org/10.1002/elan.200390102 | - |
dc.identifier.citation | Electroanalysis. Weinheim: Wiley-v C H Verlag Gmbh, v. 15, n. 9, p. 827-830, 2003. | - |
dc.identifier.issn | 1040-0397 | - |
dc.identifier.uri | http://hdl.handle.net/11449/35219 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/35219 | - |
dc.description.abstract | The design and characteristics of a novel electrochemical system, which uses a drop as a renewable electroanalytical sensor, are described. This article describes the performance of the electrochemical system, the coupling of the experimental arrangement with flow injection technique and a demonstration of its applicability for the measurement of sulfide. The method is based on renewable drops of ferricyanide ions, buffered by borate. The ferrocyanide ions, product of the reaction between ferricyanide and sulfide ions, are oxidized on a platinum microelectrode and the current measured is related to sulfide concentration. The measurements can be done in continuous or static flow mode. In continuous mode, the detection limit is 5.0 x 10(-5) mol L-1. | en |
dc.format.extent | 827-830 | - |
dc.language.iso | eng | - |
dc.publisher | Wiley-Blackwell | - |
dc.source | Web of Science | - |
dc.subject | ferricyanide | pt |
dc.subject | flow injection analysis (FIA) | pt |
dc.subject | microelectrodes | pt |
dc.title | Renewable drops electrochemical sensor for sulfide ions detection | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | UNESP, Dept Quim Analit, Inst Quim, BR-14800900 Araraquara, SP, Brazil | - |
dc.description.affiliationUnesp | UNESP, Dept Quim Analit, Inst Quim, BR-14800900 Araraquara, SP, Brazil | - |
dc.identifier.doi | 10.1002/elan.200390102 | - |
dc.identifier.wos | WOS:000183964600009 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Electroanalysis | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.