Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/35298
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pereira, Francisco Claudece | - |
dc.contributor.author | Zanoni, Maria Valnice Boldrin | - |
dc.date.accessioned | 2014-05-20T15:24:45Z | - |
dc.date.accessioned | 2016-10-25T17:59:03Z | - |
dc.date.available | 2014-05-20T15:24:45Z | - |
dc.date.available | 2016-10-25T17:59:03Z | - |
dc.date.issued | 2007-05-01 | - |
dc.identifier | http://dx.doi.org/10.1002/elan.200603815 | - |
dc.identifier.citation | Electroanalysis. Weinheim: Wiley-v C H Verlag Gmbh, v. 19, n. 9, p. 993-998, 2007. | - |
dc.identifier.issn | 1040-0397 | - |
dc.identifier.uri | http://hdl.handle.net/11449/35298 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/35298 | - |
dc.description.abstract | Sodium nitroprusside (NP), a commercial vasodilator, can be pre-concentrated on vitreous carbon electrode modified by films of 97.5%: 2.5% Poly-L-lysine (PLL): glutaraldehyde (GA). This coating gives acceptable anion exchange properties whilst giving the required improvement of adhesion to the glassy carbon electrode surface. Linear response range and detection limit on nitroprusside in B-R buffer pH 4.0, were 1 x 10(-6) to 2 x 10-(5) mol L-1 and 1 x 10(-7) mol L-1, respectively. The repeatability of the proposed sensor, evaluated in term of relative standard deviation, was measured as 4.1% for 10 experiments. The voltammetric sensor was directly applied to determination of nitroprusside in human plasma and urine samples and the average recovery for these samples was around 95-97% without any pre treatment. | en |
dc.format.extent | 993-998 | - |
dc.language.iso | eng | - |
dc.publisher | Wiley-Blackwell | - |
dc.source | Web of Science | - |
dc.subject | voltammetric sensor | pt |
dc.subject | poly-L-lysine | pt |
dc.subject | nitroprusside | pt |
dc.subject | biological fluids | pt |
dc.title | Voltammetric sensor for sodium nitroprusside determination in biological fluids using films of poly-L-lysine | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade Federal do Rio Grande do Norte (UFRN) | - |
dc.description.affiliation | UNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil | - |
dc.description.affiliation | Univ Fed Rio Grande do Norte, Dept Quim, BR-59072970 Natal, RN, Brazil | - |
dc.description.affiliationUnesp | UNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil | - |
dc.identifier.doi | 10.1002/elan.200603815 | - |
dc.identifier.wos | WOS:000246534700013 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Electroanalysis | - |
dc.identifier.orcid | 0000-0002-2296-1393 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.