You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/35888
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCastro, SSL-
dc.contributor.authorBalbo, V. R.-
dc.contributor.authorBarbeira, PJS-
dc.contributor.authorStradiotto, Nelson Ramos-
dc.date.accessioned2014-05-20T15:25:28Z-
dc.date.accessioned2016-10-25T17:59:57Z-
dc.date.available2014-05-20T15:25:28Z-
dc.date.available2016-10-25T17:59:57Z-
dc.date.issued2001-08-30-
dc.identifierhttp://dx.doi.org/10.1016/S0039-9140(01)00407-6-
dc.identifier.citationTalanta. Amsterdam: Elsevier B.V., v. 55, n. 2, p. 249-254, 2001.-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://hdl.handle.net/11449/35888-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/35888-
dc.description.abstractThe PB film-modified electrode was used as an amperometric detector for flow injection analysis of ascorbic acid. The modified electrode detector showed good sensitivity, stability and reproducibility. The calibration curve for ascorbic acid was linear over the concentration range from 5.0 x 10(-6) to 1.0 x 10(-3) mol l(-1) with a slope of 19.9 mA mol(-1) per litre and a correlation coefficient of 0.999. The detection limit of this method was 2.49 x 10(-6) mol l(-1). The relative standard deviation of six replicate injections of 2.5 x 10(-4) mol l(-1) ascorbic acid was 2.5%. The results obtained for ascorbic acid determination in pharmaceutical products are in good agreement with those obtained by using the procedure involving the reaction between triiodide and ascorbic acid. (C) 2001 Elsevier B.V. B.V. All rights reserved.en
dc.format.extent249-254-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectPrussian Bluept
dc.subjectmodified electrodept
dc.subjectascorbic acidpt
dc.subjectflow systempt
dc.subjectamperometric detectorpt
dc.titleFlow injection amperometric detection of ascorbic acid using a Prussian Blue film-modified electrodeen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.contributor.institutionUniversidade Federal de Minas Gerais (UFMG)-
dc.description.affiliationUNESP, Inst Quim, Dept Quim Analit, BR-14800900 Araraquara, SP, Brazil-
dc.description.affiliationUSP, FFCLRP, Dept Quim, BR-14040901 Ribeirao Preto, SP, Brazil-
dc.description.affiliationUniv Fed Minas Gerais, ICEX, Dept Quim Analit, BR-31270901 Belo Horizonte, MG, Brazil-
dc.description.affiliationUnespUNESP, Inst Quim, Dept Quim Analit, BR-14800900 Araraquara, SP, Brazil-
dc.identifier.doi10.1016/S0039-9140(01)00407-6-
dc.identifier.wosWOS:000171174600004-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofTalanta-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.