You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/36171
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSantini, A. O.-
dc.contributor.authorPezza, Helena Redigolo-
dc.contributor.authorPezza, Leonardo-
dc.date.accessioned2014-05-20T15:25:50Z-
dc.date.accessioned2016-10-25T18:00:24Z-
dc.date.available2014-05-20T15:25:50Z-
dc.date.available2016-10-25T18:00:24Z-
dc.date.issued2006-01-15-
dc.identifierhttp://dx.doi.org/10.1016/j.talanta.2005.05.016-
dc.identifier.citationTalanta. Amsterdam: Elsevier B.V., v. 68, n. 3, p. 636-642, 2006.-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://hdl.handle.net/11449/36171-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/36171-
dc.description.abstractThe characteristics, performance, and application of an electrode, namely Pt| Hg|Hg-2(DCF)(2)|graphite, where DCF stands for diclofenac ion, are described. This electrode responds to diclofenac with sensitivity of (58.1 +/- 0.8) mV/decade over the range 5.0 x 10(-5) to 1.0 x 10(-2) Mol l(-1) at pH 6.5-9.0 and a detection limit of 3.2 x 10(-5) mol l(-1). The electrode is easily constructed at a relatively low cost with fast response time (within 10-30 s) and can be used for a period of 5 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for diclofenac in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used to determine diclofenac in pharmaceutical preparations by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedures. (c) 2005 Elsevier B.V. All rights reserved.en
dc.format.extent636-642-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectdiclofenac-sensitive electrodept
dc.subjectpotentiometrypt
dc.subjectpharmaceutical preparationspt
dc.titleDetermination of diclofenac in pharmaceutical preparations using a potentiometric sensor immobilized in a graphite matrixen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUnespUNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.doi10.1016/j.talanta.2005.05.016-
dc.identifier.wosWOS:000234955400021-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofTalanta-
dc.identifier.orcid0000-0003-0197-7369pt
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.