You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/36611
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMascone, D.-
dc.contributor.authorYamanaka, H.-
dc.contributor.authorMascini, M.-
dc.date.accessioned2014-05-20T15:26:26Z-
dc.date.accessioned2016-10-25T18:01:04Z-
dc.date.available2014-05-20T15:26:26Z-
dc.date.available2016-10-25T18:01:04Z-
dc.date.issued1993-12-01-
dc.identifierhttps://getinfo.de/app/Biosensors-for-Glucose-Needle-Shaped-for-in-vivo/id/BLSE%3AEN016629546-
dc.identifier.citationRussian Journal of Electrochemistry. Birmingham: Interperiodica, v. 29, n. 12, p. 1339-1343, 1993.-
dc.identifier.issn1023-1935-
dc.identifier.urihttp://hdl.handle.net/11449/36611-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/36611-
dc.description.abstractDifferent procedures for obtaining a needle biosensor for the determination of glucose to be inserted subcutaneously in vivo, have been compared. Platinum wires with a diameter of 75 mum, teflon-coated were inserted in hypodermic needles and fixed with a two-component epoxy resin. Using a dip-coating procedure, several layers were deposited on electrodes. The first coating was cellulose acetate, the second was immobilized glucose oxidase (GOD) mixed with bovine serum albumin (BSA) and glutaraldheyde, the third coating was a polyurethane coating obtained with commercially available products. A large number of electrodes have been tried and statistically evaluated but they seem to be affected by poor reproducibility evidenced by a large spreading in successive calibration curves. Then, the polyurethane coating has been replaced by a thin polycarbonate membrane salinized and fixed on the tip of the needle. Reproducible results were achieved and first results of in vivo measurements on rabbits are reported.en
dc.format.extent1339-1343-
dc.language.isoeng-
dc.publisherInterperiodica-
dc.sourceWeb of Science-
dc.titleBIOSENSORS FOR GLUCOSE NEEDLE-SHAPED FOR IN-VIVO MONITORINGen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionDIP SANITA PUBBL EPIDEMIOL & CHIM ANALIT AMBIENTALE-
dc.description.affiliationUNESP,INST QUIM,BR-14800900 ARARAQUARA,BRAZIL-
dc.description.affiliationDIP SANITA PUBBL EPIDEMIOL & CHIM ANALIT AMBIENTALE,SEZ CHIM ANALIT,I-50121 FLORENCE,ITALY-
dc.description.affiliationUnespUNESP,INST QUIM,BR-14800900 ARARAQUARA,BRAZIL-
dc.identifier.wosWOS:A1993NY81100017-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofRussian Journal of Electrochemistry-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.