You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/37125
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPereira, F. C.-
dc.contributor.authorFogg, A. G.-
dc.contributor.authorZanoni, Maria Valnice Boldrin-
dc.date.accessioned2014-05-20T15:27:04Z-
dc.date.accessioned2016-10-25T18:01:48Z-
dc.date.available2014-05-20T15:27:04Z-
dc.date.available2016-10-25T18:01:48Z-
dc.date.issued2003-07-27-
dc.identifierhttp://dx.doi.org/10.1016/S0039-9140(03)00181-4-
dc.identifier.citationTalanta. Amsterdam: Elsevier B.V., v. 60, n. 5, p. 1023-1032, 2003.-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://hdl.handle.net/11449/37125-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/37125-
dc.description.abstractCromoglycate is accumulated on a poly-L-lysine (PLL) modified carbon electrode best from pH 4 solution, where it is anionic and the PLL is cationic, and at which pH the cromoglycate gives a good reduction peak at -0.82 V. The PLL film can be regenerated readily by washing the electrode with 3 M sodium hydroxide solution, in which the PLL is deprotonated. Regeneration of the film is not required as frequently when larger amounts of PLL are incorporated into it. This allows standard addition procedures to be carried out without regenerating the electrode. Linear calibration graphs have been obtained typically in the range 0.1 - 1.5 mug ml(-1). Detection limits have been calculated to be 10 ng ml(-1). The standard addition method has been applied satisfactorily to diluted urine solutions. (C) 2003 Elsevier B.V. B.V. All rights reserved.en
dc.format.extent1023-1032-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectpoly-L-lysinept
dc.subjectsodium cromoglycatept
dc.subjectmodified electrodespt
dc.subjectelectroanalysispt
dc.titleRegeneration of poly-L-lysine modified carbon electrodes in the accumulation and cathodic stripping voltammetric determination of the cromoglycate anionen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniv Luton-
dc.contributor.institutionLoughborough Univ Technol-
dc.description.affiliationUniv Estadual Paulista, Inst Quim, Dept Quim Analt, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUniv Luton, Luton Inst, Luton LU1 5DU, Beds, England-
dc.description.affiliationLoughborough Univ Technol, Loughborough LE11 3TU, Leics, England-
dc.description.affiliationUnespUniv Estadual Paulista, Inst Quim, Dept Quim Analt, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.doi10.1016/S0039-9140(03)00181-4-
dc.identifier.wosWOS:000184367700017-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofTalanta-
dc.identifier.orcid0000-0002-2296-1393-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.