Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/37125
Registro de metadados completo
Campo DCValorIdioma
dc.contributor.authorPereira, F. C.-
dc.contributor.authorFogg, A. G.-
dc.contributor.authorZanoni, Maria Valnice Boldrin-
dc.date.accessioned2014-05-20T15:27:04Z-
dc.date.accessioned2016-10-25T18:01:48Z-
dc.date.available2014-05-20T15:27:04Z-
dc.date.available2016-10-25T18:01:48Z-
dc.date.issued2003-07-27-
dc.identifierhttp://dx.doi.org/10.1016/S0039-9140(03)00181-4-
dc.identifier.citationTalanta. Amsterdam: Elsevier B.V., v. 60, n. 5, p. 1023-1032, 2003.-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://hdl.handle.net/11449/37125-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/37125-
dc.description.abstractCromoglycate is accumulated on a poly-L-lysine (PLL) modified carbon electrode best from pH 4 solution, where it is anionic and the PLL is cationic, and at which pH the cromoglycate gives a good reduction peak at -0.82 V. The PLL film can be regenerated readily by washing the electrode with 3 M sodium hydroxide solution, in which the PLL is deprotonated. Regeneration of the film is not required as frequently when larger amounts of PLL are incorporated into it. This allows standard addition procedures to be carried out without regenerating the electrode. Linear calibration graphs have been obtained typically in the range 0.1 - 1.5 mug ml(-1). Detection limits have been calculated to be 10 ng ml(-1). The standard addition method has been applied satisfactorily to diluted urine solutions. (C) 2003 Elsevier B.V. B.V. All rights reserved.en
dc.format.extent1023-1032-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectpoly-L-lysinept
dc.subjectsodium cromoglycatept
dc.subjectmodified electrodespt
dc.subjectelectroanalysispt
dc.titleRegeneration of poly-L-lysine modified carbon electrodes in the accumulation and cathodic stripping voltammetric determination of the cromoglycate anionen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniv Luton-
dc.contributor.institutionLoughborough Univ Technol-
dc.description.affiliationUniv Estadual Paulista, Inst Quim, Dept Quim Analt, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUniv Luton, Luton Inst, Luton LU1 5DU, Beds, England-
dc.description.affiliationLoughborough Univ Technol, Loughborough LE11 3TU, Leics, England-
dc.description.affiliationUnespUniv Estadual Paulista, Inst Quim, Dept Quim Analt, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.doi10.1016/S0039-9140(03)00181-4-
dc.identifier.wosWOS:000184367700017-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofTalanta-
dc.identifier.orcid0000-0002-2296-1393-
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.