You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/37247
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKurokawa, S.-
dc.contributor.authorPissolato, J.-
dc.contributor.authorTavares, M. C.-
dc.contributor.authorPortela, C. M.-
dc.contributor.authorPrado, A. J.-
dc.date.accessioned2014-05-20T15:27:13Z-
dc.date.accessioned2016-10-25T18:02:00Z-
dc.date.available2014-05-20T15:27:13Z-
dc.date.available2016-10-25T18:02:00Z-
dc.date.issued2005-04-01-
dc.identifierhttp://dx.doi.org/10.1109/TPWRD.2004.833916-
dc.identifier.citationIEEE Transactions on Power Delivery. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc., v. 20, n. 2, p. 1669-1676, 2005.-
dc.identifier.issn0885-8977-
dc.identifier.urihttp://hdl.handle.net/11449/37247-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/37247-
dc.description.abstractInitially this paper shows the ground wire reduction process for generic multiphase transmission lines and after, the ground wire reduction process for a specilic 440-kV three-phase overhead transmission line. Following this, the influence of the ground wire reduction process considering two situations is shown: first, considering frequency independence and second, when these parameters are considered as frequency dependent. This paper presents analytical results for generic multiphase transmission lines. For a specific 440-kV three-phase overhead transmission line, analytical and graphic results are shown considering real data for every frequency between 10 Hz and 1 MHz.en
dc.format.extent1669-1676-
dc.language.isoeng-
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)-
dc.sourceWeb of Science-
dc.subjectadmittance matrixpt
dc.subjectelectromagnetic (EM) fieldpt
dc.subjectfrequency-domain analysispt
dc.subjectimpedance matrixpt
dc.subjectmulticonductor transmission linespt
dc.subjecttransmission-line matrix methodspt
dc.subjecttransmission-line theorypt
dc.titleBehavior of overhead transmission line parameters on the presence of ground-wiresen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.contributor.institutionUniversidade Federal do Rio de Janeiro (UFRJ)-
dc.description.affiliationUniv Estadual Paulista, Fac Engn Ilha Solteria, BR-1538500 Ilha Solteria, Brazil-
dc.description.affiliationUniv Estadual Campinas, BR-13081970 Campinas, SP, Brazil-
dc.description.affiliationUniv Fed Rio de Janeiro, BR-21941972 Rio de Janeiro, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Fac Engn Ilha Solteria, BR-1538500 Ilha Solteria, Brazil-
dc.identifier.doi10.1109/TPWRD.2004.833916-
dc.identifier.wosWOS:000228096100059-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofIEEE Transactions on Power Delivery-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.