You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/37268
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRibeiro, LRB-
dc.contributor.authorHackspacher, P. C.-
dc.contributor.authorRibeiro, MCS-
dc.contributor.authorHadler, J. C.-
dc.contributor.authorTello, SCA-
dc.contributor.authorIunes, P. J.-
dc.contributor.authorFranco, AOB-
dc.contributor.authorGodoy, D. R.-
dc.date.accessioned2014-05-20T15:27:15Z-
dc.date.accessioned2016-10-25T18:02:01Z-
dc.date.available2014-05-20T15:27:15Z-
dc.date.available2016-10-25T18:02:01Z-
dc.date.issued2005-12-01-
dc.identifierhttp://dx.doi.org/10.1016/j.radmeas.2004.09.007-
dc.identifier.citationRadiation Measurements. Oxford: Pergamon-Elsevier B.V., v. 39, n. 6, p. 669-673, 2005.-
dc.identifier.issn1350-4487-
dc.identifier.urihttp://hdl.handle.net/11449/37268-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/37268-
dc.description.abstractThe Precambrian crystalline basement of southeast Brazil is affected by many Phanerozoic reactivations of shear zones that developed during the end of the Neoproterozoic in the Brasiliano orogeny. These reactivations with specific tectonic events, a multidisciplinary study was done, involving geology, paleostress, and structural analysis of faults, associated with apatite fission track methods along the northeastern border of the Parana basin in southeast Brazil.The results show that the study area consists of three main tectonic domains, which record different episodes of uplift and reactivation of faults. These faults were brittle in character and resulted in multiple generations of fault products as pseudotachylytes and ultracataclasites, foliated cataclasites and fault gouges.Based on geological evidence and fission track data, an uplift of basement rocks and related tectonic subsidence with consequent deposition in the Parana basin were modeled.The reactivations of the basement record successive uplift events during the Phanerozoic dated via corrected fission track ages, at 387 +/- 50 Ma (Ordovician); 193 +/- 19 Ma (Triassic); 142 +/- 18 Ma (Jurassic), 126 +/- 11 Ma (Early Cretaceous); 89 +/- 10 Ma (Late Cretaceous) and 69 +/- 10 Ma (Late Cretaceous). These results indicate differential uplift of tectonic domains of basement units, probably related to Parana basin subsidence. Six major sedimentary units (supersequences) that have been deposited with their bounding unconformities, seem to have a close relationship with the orogenic events during the evolution of southwestern Gondwana. (c) 2005 Elsevier Ltd. All rights reserved.en
dc.format.extent669-673-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectfission track datingpt
dc.subjectreactivationspt
dc.subjectthermochronology in Brazilpt
dc.subjectParana basinpt
dc.titleThermotectonic and fault dynamic analysis of Precambrian basement and tectonic constraints with the Parana basinen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.description.affiliationUNESP, IGCE, BR-13250690 Rio Claro, SP, Brazil-
dc.description.affiliationUNICAMP, IFGW, BR-13081970 Campinas, SP, Brazil-
dc.description.affiliationUNESP, DF, BR-13506700 Presidente Prudente, SP, Brazil-
dc.description.affiliationUnespUNESP, IGCE, BR-13250690 Rio Claro, SP, Brazil-
dc.description.affiliationUnespUNESP, DF, BR-13506700 Presidente Prudente, SP, Brazil-
dc.identifier.doi10.1016/j.radmeas.2004.09.007-
dc.identifier.wosWOS:000229716600018-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofRadiation Measurements-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.