You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/37382
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWakabayashi, F. T.-
dc.contributor.authorDantas, F. D.-
dc.contributor.authorPinto, J O P-
dc.contributor.authorCanesin, C. A.-
dc.contributor.authorIEEE-
dc.date.accessioned2014-05-20T15:27:23Z-
dc.date.accessioned2016-10-25T18:02:12Z-
dc.date.available2014-05-20T15:27:23Z-
dc.date.available2016-10-25T18:02:12Z-
dc.date.issued2005-01-01-
dc.identifierhttp://dx.doi.org/10.1109/PESC.2005.1581772-
dc.identifier.citation2005 IEEE 36th Power Electronic Specialists Conference (pesc), Vols 1-3. New York: IEEE, p. 1136-1141, 2005.-
dc.identifier.issn0275-9306-
dc.identifier.urihttp://hdl.handle.net/11449/37382-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/37382-
dc.description.abstractThis paper presents a new methodology for the determination of fluorescent lamp models based on equivalent resistances. One important feature of the proposed methodology is concerned with the inclusion of the filaments into the model, considering the effects of dimming operation on the equivalent resistances. The classical Series-Resonant Parallel-Loaded Half-Bridge inverter is used as the power stage of the ballast. Moreover, the variation of the inverter's switching frequency is the dimming technique assumed for the analyses. Results obtained with a F32T8 lamp indicate that the accuracy of the model is very satisfactory. Thus, the lamp models obtained with the proposed methodology have the potential to serve as an important tool for ballast designers, considering the necessity for evaluating the lamp/ballast compatibility, according to issues concerned to the operating conditions of the electrodes' filaments.en
dc.format.extent1136-1141-
dc.language.isoeng-
dc.publisherIEEE-
dc.sourceWeb of Science-
dc.titleFluorescent lamp model based on equivalent resistances, considering the effects of dimming operationen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP, BR-15385000 Ilha Solteira, SP, Brazil-
dc.description.affiliationUnespUNESP, BR-15385000 Ilha Solteira, SP, Brazil-
dc.identifier.doi10.1109/PESC.2005.1581772-
dc.identifier.wosWOS:000237036501025-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartof2005 IEEE 36th Power Electronic Specialists Conference (pesc), Vols 1-3-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.