dc.contributor.authorFranzini, Vanessa Pezza-
dc.contributor.authorFugivara, Cecilio Sadao-
dc.contributor.authorBenedetti, Assis Vicente-
dc.contributor.authorRibeiro, Clovis Augusto-
dc.contributor.authorCavalheiro, Eder Tadeu Gomes-
dc.contributor.authorGomes Neto, José Anchieta-
dc.date.accessioned2014-05-20T15:27:31Z-
dc.date.accessioned2016-10-25T18:02:21Z-
dc.date.available2014-05-20T15:27:31Z-
dc.date.available2016-10-25T18:02:21Z-
dc.date.issued2007-09-01-
dc.identifierhttp://dx.doi.org/10.1002/elan.200703935-
dc.identifier.citationElectroanalysis. Weinheim: Wiley-v C H Verlag Gmbh, v. 19, n. 17, p. 1794-1798, 2007.-
dc.identifier.issn1040-0397-
dc.identifier.urihttp://hdl.handle.net/11449/37472-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/37472-
dc.description.abstractA sensor based on graphite electrode modified with palladium-platinum-palladium film is proposed for phosphite determination by flow-injection amperometry. The modified electrode was prepared by a sequential cathodic deposition of Pd, Pt and Pd on a graphite electrode from 0.5% m/v PdCl2 + 28% m/v NH4OH and 2% m/v H2PtCl6 + 10% v/v H2SO4 solutions. After suitable conditioning, the electrode showed catalytic activity for phosphite oxidation when 0. 15 V was applied. The proposed system handles approximately 50 samples per hour (0.0.1 - 0.05 mol L-1 Na-2 HPO3; R-2 = 0.9997), consuming ca. 70 mu L of sample per determination. The limit of detection and amperometric sensibility were 5 X 10(-4) mol L-1 and 1.5 mA L mol(-1), respectively. The proposed method was applied to analysis of fertilizer samples without pre-treatment. Results are in agreement with those obtained by spectrophotometry and titrimetry at 95% confidence level and good recoveries (96-109%) of spiked samples were found. Relative standard deviation (n=12) of a 0.01 mol L-1 Na2HPO3 sample was 2%. The useful lifetime of modified electrode was around 220 determinations. For routine purposes it means that this electrode can be continuously used for 5 hours.en
dc.format.extent1794-1798-
dc.language.isoeng-
dc.publisherWiley-Blackwell-
dc.sourceWeb of Science-
dc.subjectphosphitept
dc.subjectfertilizerpt
dc.subjectmodified electrodept
dc.subjectflow-injection analysispt
dc.titleDirect determination of phosphite in fertilizers by flow-injection amperometryen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.description.affiliationUniv Estadual Paulista, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUniv São Paulo, Inst Quim, BR-13560970 Sao Carlos, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.doi10.1002/elan.200703935-
dc.identifier.wosWOS:000249294800007-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofElectroanalysis-
dc.identifier.orcid0000-0002-7984-5908pt