You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/37572
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGomes, ACF-
dc.contributor.authorMenegario, A. A.-
dc.contributor.authorPellegrinotti, D. C.-
dc.contributor.authorGine, M. F.-
dc.contributor.authorNascimento, V. F.-
dc.date.accessioned2014-05-20T15:27:37Z-
dc.date.accessioned2016-10-25T18:02:29Z-
dc.date.available2014-05-20T15:27:37Z-
dc.date.available2016-10-25T18:02:29Z-
dc.date.issued2004-09-20-
dc.identifierhttp://dx.doi.org/10.1016/j.sab.2004.06.007-
dc.identifier.citationSpectrochimica Acta Part B-atomic Spectroscopy. Oxford: Pergamon-Elsevier B.V., v. 59, n. 9, p. 1481-1484, 2004.-
dc.identifier.issn0584-8547-
dc.identifier.urihttp://hdl.handle.net/11449/37572-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/37572-
dc.description.abstractIn this work, a preconcentration and separation system based on continuous flow hydride generation is proposed to improve the determination of As and Se by total reflection X-ray fluorescence spectrometry. The generated hydrides are continuously separated from the liquid phase and collected in a chamber containing 250 mul of HCI/HNO3 1:1 (v/v) solution. Hydride generation conditions and collection of the hydrides were evaluated. Under optimised conditions, enrichment factors of 55 for As and 82 for Se were attained. Detection limits of 0.3 mug l(-1) for As and Se were obtained when 20 ml of sample was used. Analysis of a natural water standard reference material from National Institute of Standard and Technology (SRM-1640) was in agreement with the certified values at the 95% confidence level. (C) 2004 Elsevier B.V. All rights reserved.en
dc.format.extent1481-1484-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectTXRFpt
dc.subjecthydride generationpt
dc.subjectflow systempt
dc.subjectpreconcentrationpt
dc.titleA hydride generation flow system for determination of arsenic and selenium by total reflection X-ray fluorescence spectrometryen
dc.typeoutro-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv São Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil-
dc.description.affiliationUniv Estadual Paulista, Ctr Estudos Ambientais, BR-13506900 Rio Claro, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Ctr Estudos Ambientais, BR-13506900 Rio Claro, SP, Brazil-
dc.identifier.doi10.1016/j.sab.2004.06.007-
dc.identifier.wosWOS:000224589900016-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofSpectrochimica Acta Part B-atomic Spectroscopy-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.