Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/37767
Registro de metadados completo
Campo DCValorIdioma
dc.contributor.authorLessi, P.-
dc.contributor.authorDias, N. L.-
dc.contributor.authorMoreira, J. C.-
dc.contributor.authorCampos, JTS-
dc.date.accessioned2014-05-20T15:27:51Z-
dc.date.accessioned2016-10-25T18:02:46Z-
dc.date.available2014-05-20T15:27:51Z-
dc.date.available2016-10-25T18:02:46Z-
dc.date.issued1996-06-28-
dc.identifierhttp://dx.doi.org/10.1016/0003-2670(96)00074-8-
dc.identifier.citationAnalytica Chimica Acta. Amsterdam: Elsevier B.V., v. 327, n. 2, p. 183-190, 1996.-
dc.identifier.issn0003-2670-
dc.identifier.urihttp://hdl.handle.net/11449/37767-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/37767-
dc.description.abstractSilica gel, chemically modified with 2,5-dimercapto-1,3,4-thiadiazole [=Si(CH2)(3)-NC2HNS3], abbreviated as SiB, was used to adsorb metal ions from ethanol by both batch and column techniques. Elution of Cu(II) was done with a solvent mixture of acetone and hydrochloric acid (9:1 v/v). Zn(II), Cd(II), Ni(II), Pb(II), Co(II) and Fe(III) were eluted with 0.5 mol l(-1) HC1 in ethanol solution. The modified silica was applied in the preconcentration of metal ions from commercial ethanol, normally used as engine fuel. The method is suitable for quantifying these metals at low mu g l(-1) levels.en
dc.format.extent183-190-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectpreconcentrationpt
dc.subjectsilica gel functionalizedpt
dc.subject2,5-dimercapto-1,3,4-thiadiazolept
dc.subjectbismuthol Ipt
dc.titleSorption and preconcentration of metal ions on silica gel modified with 2,5-dimercapto-1,3,4-thiadiazoleen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP,DEPT QUIM FIS,BR-15385000 ILHA SOLTEIRA,SP,BRAZIL-
dc.description.affiliationUNESP,INST QUIM,BR-14800900 ARARAQUARA,SP,BRAZIL-
dc.description.affiliationUnespUNESP,DEPT QUIM FIS,BR-15385000 ILHA SOLTEIRA,SP,BRAZIL-
dc.description.affiliationUnespUNESP,INST QUIM,BR-14800900 ARARAQUARA,SP,BRAZIL-
dc.identifier.doi10.1016/0003-2670(96)00074-8-
dc.identifier.wosWOS:A1996UY09200014-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAnalytica Chimica Acta-
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.