Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/37843
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Higuti, Ricardo Tokio | - |
dc.contributor.author | Galindo, Bruno Shintate | - |
dc.contributor.author | Kitano, Claudio | - |
dc.contributor.author | Buiochi, Flavio | - |
dc.contributor.author | Adamowski, Julio Cezar | - |
dc.date.accessioned | 2014-05-20T15:27:56Z | - |
dc.date.accessioned | 2016-10-25T18:02:54Z | - |
dc.date.available | 2014-05-20T15:27:56Z | - |
dc.date.available | 2016-10-25T18:02:54Z | - |
dc.date.issued | 2007-06-01 | - |
dc.identifier | http://dx.doi.org/10.1109/TIM.2007.894225 | - |
dc.identifier.citation | IEEE Transactions on Instrumentation and Measurement. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc., v. 56, n. 3, p. 924-930, 2007. | - |
dc.identifier.issn | 0018-9456 | - |
dc.identifier.uri | http://hdl.handle.net/11449/37843 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/37843 | - |
dc.description.abstract | An ultrasonic density-measurement cell is experimentally characterized as a function of temperature. The measurement of propagation velocity and density of several liquids is performed in the 15 degrees C-40 degrees C temperature range. Results are compared to the tabulated values in the case of distilled water, showing an accuracy of 0.07% for the propagation velocity. The cell was tested with distilled water, alcohol, and homogenized milk, and density values are compared to those obtained with a pycnometer, showing 0.2% accuracy in density measurement for stabilized temperature and 0.4% accuracy under thermal gradient conditions. | en |
dc.format.extent | 924-930 | - |
dc.language.iso | eng | - |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | - |
dc.source | Web of Science | - |
dc.subject | density | pt |
dc.subject | liquid propertiesi measurement cell | pt |
dc.subject | temperature | pt |
dc.subject | ultrasonic | pt |
dc.subject | velocity | pt |
dc.title | Thermal characterization of an ultrasonic density-measurement cell | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Staner Eletron | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.description.affiliation | Univ Estadual Paulista, Dept Elect Engn, BR-15385000 São Paulo, Brazil | - |
dc.description.affiliation | Staner Eletron, BR-1900197 Presidente Prudente, Brazil | - |
dc.description.affiliation | Univ São Paulo, Dept Mechatron Engn, BR-15385000 São Paulo, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista, Dept Elect Engn, BR-15385000 São Paulo, Brazil | - |
dc.identifier.doi | 10.1109/TIM.2007.894225 | - |
dc.identifier.wos | WOS:000246590800032 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | IEEE Transactions on Instrumentation and Measurement | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.