Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/37847
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bergamini, Marcio F. | - |
dc.contributor.author | dos Santos, Daniela P. | - |
dc.contributor.author | Zanoni, Maria Valnice Boldrin | - |
dc.date.accessioned | 2014-05-20T15:27:56Z | - |
dc.date.accessioned | 2016-10-25T18:02:54Z | - |
dc.date.available | 2014-05-20T15:27:56Z | - |
dc.date.available | 2016-10-25T18:02:54Z | - |
dc.date.issued | 2007-05-21 | - |
dc.identifier | http://dx.doi.org/10.1016/j.snb.2006.10.062 | - |
dc.identifier.citation | Sensors and Actuators B-chemical. Lausanne: Elsevier B.V. Sa, v. 123, n. 2, p. 902-908, 2007. | - |
dc.identifier.issn | 0925-4005 | - |
dc.identifier.uri | http://hdl.handle.net/11449/37847 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/37847 | - |
dc.description.abstract | Screen-printed carbon electrode (SPCE) modified with poly-L-histidine film can be successfully applied for chromium(VI) determination based on its pre-concentration. Optimum adherence and stability of the POIY-L-histidine film was obtained by direct addition of PH solution 1% (w/v) on the electrode surface, followed by heating at 80 degrees C during 5 min. Linear response range, sensitivity and limit of detection were 0. 1-150 [mu mol L-1, 4. 13 LA mu mol L` and 0.046 mu mol L-1. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation, was measured as 3.2% for 10 experiments in 40 mu mol L-1 using the same electrode and 4.0% using screen-printed electrode as disposable sensor, respectively. The voltammetric sensor was applied to determination of Cr(VI) and indirect determination of Cr(III) in wastewater samples previously treated by a leather dyeing industry and the average recovery for these samples was around 97%. (C) 2006 Elsevier B.V. All rights reserved. | en |
dc.format.extent | 902-908 | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier B.V. | - |
dc.source | Web of Science | - |
dc.subject | chromium(VI) | pt |
dc.subject | stripping analysis | pt |
dc.subject | screen-printed modified electrode | pt |
dc.subject | poly-L-histidine | pt |
dc.title | Development of a voltammetric sensor for chromium(VI) determination in wastewater sample | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | UNESP, Dept Quim Analit, Inst Quim, BR-14801970 Araraquara, Brazil | - |
dc.description.affiliationUnesp | UNESP, Dept Quim Analit, Inst Quim, BR-14801970 Araraquara, Brazil | - |
dc.identifier.doi | 10.1016/j.snb.2006.10.062 | - |
dc.identifier.wos | WOS:000247060100037 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Sensors and Actuators B: Chemical | - |
dc.identifier.orcid | 0000-0002-2296-1393 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.