You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/38046
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMilani, M. R.-
dc.contributor.authorCardoso, Arnaldo Alves-
dc.date.accessioned2014-05-20T15:28:11Z-
dc.date.accessioned2016-10-25T18:03:10Z-
dc.date.available2014-05-20T15:28:11Z-
dc.date.available2016-10-25T18:03:10Z-
dc.date.issued2003-02-01-
dc.identifierhttp://dx.doi.org/10.1016/S0026-265X(02)00173-X-
dc.identifier.citationMicrochemical Journal. Amsterdam: Elsevier B.V., v. 74, n. 1, p. 75-82, 2003.-
dc.identifier.issn0026-265X-
dc.identifier.urihttp://hdl.handle.net/11449/38046-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/38046-
dc.description.abstractA nephelometric technique based on a liquid drop is described for the measurement of atmospheric sulfur dioxide. A 40-mul drop of barium chloride and hydrogen peroxide solution is suspended in a flowing-air sampling stream. The sulfur (IV) collected is oxidized to sulfur (VI) and finally precipitated as barium sulfate. Nephelometric detection of drop is achieved by an appropriate arrangement consisting of an optical fiber contacting the drop and a photodiode placed at 90degrees relative to the fiber. The design and characteristics of this drop-based gas sensor system are described. The analytical response, as photocurrent, is proportional to the product of the sampling period and the sulfur dioxide concentration. The detection limit is ca. 1.1 mg m(-3) for a 10-min sampling time. The present technique is fairly rapid and simple, uses a small amount of reagent and is set up with low-cost equipment, making this system economically viable. (C) 2002 Elsevier B.V. B.V. All rights reserved.en
dc.format.extent75-82-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectnephelometrypt
dc.subjectsulfur dioxide determinationpt
dc.subjectdrop analysispt
dc.titleConstruction and performance of a drop cell for the nephelometric determination of sulfur dioxideen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP, Inst Quim, Dept Quim Analit, BR-14800900 Araraquara, SP, Brazil-
dc.description.affiliationUnespUNESP, Inst Quim, Dept Quim Analit, BR-14800900 Araraquara, SP, Brazil-
dc.identifier.doi10.1016/S0026-265X(02)00173-X-
dc.identifier.wosWOS:000181333000007-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofMicrochemical Journal-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.