Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/38460
Registro de metadados completo
Campo DCValorIdioma
dc.contributor.authorFernandes, V. J.-
dc.contributor.authorAraujo, A. S.-
dc.contributor.authorFernandes, GJT-
dc.contributor.authorMatos, JR-
dc.contributor.authorIonashiro, Massao-
dc.date.accessioned2014-05-20T15:28:42Z-
dc.date.accessioned2016-10-25T18:03:50Z-
dc.date.available2014-05-20T15:28:42Z-
dc.date.available2016-10-25T18:03:50Z-
dc.date.issued2001-01-01-
dc.identifierhttp://dx.doi.org/10.1023/A:1011511504478-
dc.identifier.citationJournal of Thermal Analysis and Calorimetry. Dordrecht: Springer, v. 64, n. 2, p. 585-589, 2001.-
dc.identifier.issn1388-6150-
dc.identifier.urihttp://hdl.handle.net/11449/38460-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/38460-
dc.description.abstractHigh density poly(ethylene) has been submitted to thermal degradation alone, and in the presence of silicoaluminophosphate SAPO-37. The processes were carried out in a reactor connected on line to a gas chromatograph/mass spectrometer in order to analyze the evolved products. Polymer degradation was also evaluated by thermogravimetry, from room temperature until 800 degreesC, under nitrogen dynamic atmosphere, with multiple heating rates. From TG curves, the activation energy related to degradation process was calculated using the Flynn and Wall multiple heating rate kinetic model for pure polymer (PE) and for polymer in the presence of catalyst (PE/S37). SAPO-37 showed good selectivity for low molecular mass hydrocarbons in PE catalytic degradation.en
dc.format.extent585-589-
dc.language.isoeng-
dc.publisherSpringer-
dc.sourceWeb of Science-
dc.subjectFlynn and Wall kinetic modelpt
dc.subjectpoly(ethylene) degradationpt
dc.subjectSAPO-37pt
dc.titleKinetic parameters of polymer degradation by SAPO-37en
dc.typeoutro-
dc.contributor.institutionUniversidade Federal do Rio Grande do Norte (UFRN)-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Fed Rio Grande Norte, Dept Quim, BR-59078970 Natal, RN, Brazil-
dc.description.affiliationUniv São Paulo, Inst Quim, BR-05508900 São Paulo, Brazil-
dc.description.affiliationUniv Estadual Paulista, Inst Quim, BR-14800900 Araraquara, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Inst Quim, BR-14800900 Araraquara, SP, Brazil-
dc.identifier.doi10.1023/A:1011511504478-
dc.identifier.wosWOS:000168679600019-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Thermal Analysis and Calorimetry-
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.