You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/38476
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCavalcanti, B. N.-
dc.contributor.authorOtani, C.-
dc.contributor.authorRode, S. M.-
dc.date.accessioned2014-05-20T15:28:43Z-
dc.date.accessioned2016-10-25T18:03:51Z-
dc.date.available2014-05-20T15:28:43Z-
dc.date.available2016-10-25T18:03:51Z-
dc.date.issued2002-02-01-
dc.identifierhttp://dx.doi.org/10.1067/mpr.2002.120655-
dc.identifier.citationJournal of Prosthetic Dentistry. St Louis: Mosby, Inc., v. 87, n. 2, p. 158-161, 2002.-
dc.identifier.issn0022-3913-
dc.identifier.urihttp://hdl.handle.net/11449/38476-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/38476-
dc.description.abstractStatement of problem. Cavity and tooth preparations generate heat because the use of rotary cutting instruments on dental tissues creates friction. Dental pulps cannot survive temperature increases greater than 5.5degreesC.Purpose. This study evaluated the efficiency of 3 different water flows for 2 different tooth preparation techniques to determine which are safe for use.Material and methods. Thermocouples were placed in the pulpal chambers of 30 bovine teeth, and 1 of 2 tooth preparation techniques was used: a low-load intermittent tooth preparation technique or a high-load tooth preparation technique without intervals. Water flows of 0, 30, and 45 mL/min were associated with each technique, for a total of 6 different groups. The results were analyzed with a 2-factor analysis of variance (P<.05).Results. Temperature increases with the high-load technique were 16.40&DEG;C without cooling (group 1), 11.68&DEG;C with 30 mL/min air-water spray cooling (group III), and 9.96&DEG;C with 45 mL/min cooling (group V). With the low-load tooth preparation technique, a 9.54&DEG;C increase resulted with no cooling (group II), a 1.56&DEG;C increase with 30 mL/min air-water spray cooling (group TV), and a 0.04&DEG;C decrease with 45 mL/min cooling (group VI). The low-load technique was associated with more ideal temperature changes.Conclusion. The results of this study confirm the necessity of using a low-load technique and water coolants during cavity and tooth preparation procedures.en
dc.format.extent158-161-
dc.language.isoeng-
dc.publisherMosby, Inc-
dc.sourceWeb of Science-
dc.titleHigh-speed cavity preparation techniques with different water flowsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionInstituto Tecnológico de Aeronáutica (ITA)-
dc.description.affiliationUNESP, Sch Dent, Dept Dent Mat & Prosthet, Master Sci Program, São Paulo, Brazil-
dc.description.affiliationTechnol Inst Aeronaut, Dept Phys, São Paulo, Brazil-
dc.description.affiliationUnespUNESP, Sch Dent, Dept Dent Mat & Prosthet, Master Sci Program, São Paulo, Brazil-
dc.identifier.doi10.1067/mpr.2002.120655-
dc.identifier.wosWOS:000174270900010-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Prosthetic Dentistry-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.