You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/38483
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGuaratini, CCI-
dc.contributor.authorFogg, A. G.-
dc.contributor.authorZanoni, Maria Valnice Boldrin-
dc.date.accessioned2014-05-20T15:28:43Z-
dc.date.accessioned2016-10-25T18:03:52Z-
dc.date.available2014-05-20T15:28:43Z-
dc.date.available2016-10-25T18:03:52Z-
dc.date.issued2001-09-01-
dc.identifierhttp://dx.doi.org/10.1016/S0143-7208(01)00050-X-
dc.identifier.citationDyes and Pigments. Oxford: Elsevier B.V., v. 50, n. 3, p. 211-221, 2001.-
dc.identifier.issn0143-7208-
dc.identifier.urihttp://hdl.handle.net/11449/38483-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/38483-
dc.description.abstractTwo reactive dyes, C.I. Reactive Red 120 (RR120) and C.I. Reactive Green 19 (RG19), each bearing two azo groups as the chromophoric moiety and two monochloro-s-triazine groups as reactive groups, can be detected at nanomolar levels using cathodic stripping voltammetry. Linear calibration graphs were obtained for both reactive dyes, from 0.015 to 0.14 mu mol l(-1) for RR120 in pH 4 buffer and from 0.012 to 0.26 mu mol l(-1) for RG19 in pH 3 buffer, using a preconcentration at 0 V during 180 and 240 s on the mercury electrode, respectively. (C) 2001 Elsevier B.V. Ltd. All rights reserved.en
dc.format.extent211-221-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectreactive dyespt
dc.subjectcathodic stripping voltammetrypt
dc.subjectdye hydrolysispt
dc.subjectdye determinationpt
dc.titleAssessment of the application of cathodic stripping voltammetry to the analysis of diazo reactive dyes and their hydrolysis productsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniv Luton-
dc.contributor.institutionLoughborough Univ Technol-
dc.description.affiliationUNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUniv Luton, Res Ctr, Sensors & Cryobiol Res Grp, Luton LU1 5DU, Beds, England-
dc.description.affiliationLoughborough Univ Technol, Dept Chem, Loughborough LE11 3TU, Leics, England-
dc.description.affiliationUnespUNESP, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.doi10.1016/S0143-7208(01)00050-X-
dc.identifier.wosWOS:000171345800006-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofDyes and Pigments-
dc.identifier.orcid0000-0002-2296-1393-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.