You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/39714
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMarafão, Fernando Pinhabel-
dc.contributor.authorColon, D.-
dc.contributor.authorJardini, J. A.-
dc.contributor.authorKomatsu, W.-
dc.contributor.authorMatakas, L.-
dc.contributor.authorGalassi, M.-
dc.contributor.authorAhn, S. U.-
dc.contributor.authorBormio, E.-
dc.contributor.authorCamargo, J. C.-
dc.contributor.authorMonteiro, T.-
dc.contributor.authorOliveira, M. A.-
dc.date.accessioned2014-05-20T15:30:18Z-
dc.date.accessioned2016-10-25T18:05:45Z-
dc.date.available2014-05-20T15:30:18Z-
dc.date.available2016-10-25T18:05:45Z-
dc.date.issued2008-01-01-
dc.identifier.citation2008 13th International Conference on Harmonics and Quality of Power, Vols 1 and 2. New York: IEEE, p. 669-674, 2008.-
dc.identifier.issn1540-6008-
dc.identifier.urihttp://hdl.handle.net/11449/39714-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/39714-
dc.description.abstractThis paper deals with the design and analysis of a Dynamic Voltage Restorer output voltage control. Such control is based on a multiloop strategy, with an inner current PID regulator and an outer P+Resonant voltage controller. The inner regulator is applied on the output inductor current. It will be also demonstrated how the load current behavior may influence in the DVR output voltage, which. justifies the need for the resonant controller. Additionally, it will be discussed the application of a modified algorithm for the identification of the DVR voltage references, which is based on a previously presented positive sequence detector. Since the studied three-phase DVR is assumed to be based on three identical H-bridge converters, all the analysis and design procedures were realized by means of single-phase equivalent circuits. The discussions and conclusions are supported by theoretical calculations, nonlinear simulations and some experimental results.en
dc.format.extent669-674-
dc.language.isoeng-
dc.publisherIEEE-
dc.sourceWeb of Science-
dc.subjectDynamic Voltage Restoreren
dc.subjectPower Electronics Convertersen
dc.subjectFeedback Control Systemsen
dc.subjectPositive Sequenceen
dc.subjectResonant Controlleren
dc.titleMnltiloop Controller and Reference Generator for a Dynamic Voltage Restorer Implementationen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Estadual Paulista, Grp Automat & Integrating Syst, Sorocaba, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Grp Automat & Integrating Syst, Sorocaba, SP, Brazil-
dc.identifier.wosWOS:000262985500115-
dc.relation.ispartof2008 13th International Conference on Harmonics and Quality of Power, Vols 1 and 2-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.