You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/39751
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBarbosa, Ana P.-
dc.contributor.authorda Silva, Alessandra F.-
dc.contributor.authorZimback, Célia Regina Lopes-
dc.date.accessioned2014-05-20T15:30:21Z-
dc.date.accessioned2016-10-25T18:05:49Z-
dc.date.available2014-05-20T15:30:21Z-
dc.date.available2016-10-25T18:05:49Z-
dc.date.issued2012-06-01-
dc.identifierhttp://dx.doi.org/10.1590/S1415-43662012000600010-
dc.identifier.citationRevista Brasileira de Engenharia Agricola E Ambiental. Joao Pessoa Pb: Universidade Federal da Paraíba (UFPB) Ccsa, v. 16, n. 6, p. 655-660, 2012.-
dc.identifier.issn1415-4366-
dc.identifier.urihttp://hdl.handle.net/11449/39751-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/39751-
dc.description.abstractThe digital elevation model is important to determine the slope and land use capability, therefore, a proposal of methodology for acquisition of elevation data contemplating an efficient algorithm to generate a slope map was developed. Thus, it was aimed to obtain and evaluate a digital elevation model without the vetorization of the contours on planialtimetric charts. The area for acquisition of elevation data was Sao Manuel, SP. The data were collected by two methods: level contour vetorization and the gathering of elevation points on the level contour with maximum elevation points. The elevation data were analyzed by geostatistical techniques. Inspite of wide difference in the number of collected points between two methods, the variograms were adjusted to the exponential model and showed a range of approximately 1500 m, which does not justify the wide difficulty in vetorization of the planialtimetric charts, once the data points collected in the area were appropriately distributed, they represented rightly the terrain surface.en
dc.format.extent655-660-
dc.language.isopor-
dc.publisherUniversidade Federal da Paraíba (UFPB) Ccsa-
dc.sourceWeb of Science-
dc.subjectinterpolationen
dc.subjectkrigingen
dc.subjectslopeen
dc.titleModelo numérico do terreno obtido por diferentes métodos em cartas planialtimétricaspt
dc.title.alternativeDigital terrain model obtained by different methods in planialtimetric chartsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationFCA UNESP, BR-18610307 Botucatu, SP, Brazil-
dc.description.affiliationUnespFCA UNESP, BR-18610307 Botucatu, SP, Brazil-
dc.identifier.wosWOS:000310694700010-
dc.rights.accessRightsAcesso aberto-
dc.relation.ispartofRevista Brasileira de Engenharia Agrícola e Ambiental-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.