You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/39760
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSantos, Gildo Coelho-
dc.contributor.authorPassos, Sheila Pestana-
dc.contributor.authorMoraes Coelho Santos, Maria Jacinta-
dc.date.accessioned2014-05-20T15:30:22Z-
dc.date.accessioned2016-10-25T18:05:50Z-
dc.date.available2014-05-20T15:30:22Z-
dc.date.available2016-10-25T18:05:50Z-
dc.date.issued2011-01-01-
dc.identifierhttp://www.ncbi.nlm.nih.gov/pubmed/21210000-
dc.identifier.citationInternational Journal of Prosthodontics. Hanover Park: Quintessence Publishing Co Inc, v. 24, n. 1, p. 38-39, 2011.-
dc.identifier.issn0893-2174-
dc.identifier.urihttp://hdl.handle.net/11449/39760-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/39760-
dc.description.abstractThe purpose of this study was to determine the accuracy of mechanical torque devices in delivering target torque values in dental offices in Salvador, Brazil. A team of researchers visited 16 dental offices, and the clinicians applied torque values (20 and 32 Ncm) to electronic torque controllers. Five repetitions were completed at each torque value and data were collected. When 20 Ncm of torque was used, 62.5% of measured values were accurate (within 10% of the target value). For 32 Ncm, however, only 37.5% of these values were achieved. Several of the tested mechanical torque devices were inaccurate. Int J Prosthodont 2011;24:38-39.en
dc.format.extent38-39-
dc.language.isoeng-
dc.publisherQuintessence Publishing Co Inc-
dc.sourceWeb of Science-
dc.titleAccuracy of Mechanical Torque Devices for Implants Used in Brazilian Dental Officesen
dc.typeoutro-
dc.contributor.institutionUniv Western Ontario-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Western Ontario, Schulich Sch Med & Dent, Dept Restorat Dent, London, on N6A 5C1, Canada-
dc.description.affiliationSão Paulo State Univ, Dept Dent Mat & Prosthodont, São Paulo, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Dept Dent Mat & Prosthodont, São Paulo, Brazil-
dc.identifier.wosWOS:000287062600005-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofInternational Journal of Prosthodontics-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.