Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/40009
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Silva, C. S. | - |
dc.contributor.author | Blanco, T. | - |
dc.contributor.author | Nobrega, J. A. | - |
dc.date.accessioned | 2014-05-20T15:30:41Z | - |
dc.date.accessioned | 2016-10-25T18:06:16Z | - |
dc.date.available | 2014-05-20T15:30:41Z | - |
dc.date.available | 2016-10-25T18:06:16Z | - |
dc.date.issued | 2002-01-09 | - |
dc.identifier | http://dx.doi.org/10.1016/S0584-8547(01)00361-5 | - |
dc.identifier.citation | Spectrochimica Acta Part B-atomic Spectroscopy. Oxford: Pergamon-Elsevier B.V., v. 57, n. 1, p. 29-33, 2002. | - |
dc.identifier.issn | 0584-8547 | - |
dc.identifier.uri | http://hdl.handle.net/11449/40009 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/40009 | - |
dc.description.abstract | The feasibility of Portland cement analysis by introduction of slurries in an inductively coupled plasma optical emission spectrometer (ICP-OES) with axial viewing has been evaluated. After a fast manual grinding of the cement samples, owing to the pulverized state of this material, 0.1% m/v slurries were prepared in 1% v/v HCl. The calibration was performed adopting two strategies: one based on slurries prepared from different masses (50, 75, 100 and 125 mg) of a Portland cement standard reference material (NIST SRM 1881), and the other one based on aqueous reference solutions. A complete analysis of cement for major (Al, Ca, Fe, Mg and Si), minor and trace elements (Mn, P, S, Sr and Ti) was accomplished. Both strategies led to accurate results for commercial Portland cement samples, except for Si and Ti. for which the calibration with aqueous reference solutions resulted in low values. Applying a paired t-test it was shown that most results were in agreement at a 95% confidence level with a conventional fusion decomposition procedure. The ICP-OES with axial viewing and end-on gas configuration for removal of the recombination plasma zone was effective for cement slurry analysis without any undesirable particle deposition in the pre-optics interface and without severe spectral interferences. (C) 2002 Elsevier B.V. B.V. All rights reserved. | en |
dc.format.extent | 29-33 | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier B.V. | - |
dc.source | Web of Science | - |
dc.subject | cement slurries | pt |
dc.subject | inductively coupled plasma optical emission spectrometry | pt |
dc.subject | axial viewing | pt |
dc.title | Analysis of cement slurries by inductively coupled plasma optical emission spectrometry with axial viewing | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Federal de São Carlos (UFSCar) | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Univ Fed Sao Carlos, Dept Quim, Grp Anal Instrumental Aplicada, BR-13560970 Sao Carlos, SP, Brazil | - |
dc.description.affiliation | UNESP, UFSCar, Ctr Caracterizacao & Desenvolvimento Mat, Sao Carlos, SP, Brazil | - |
dc.description.affiliationUnesp | UNESP, UFSCar, Ctr Caracterizacao & Desenvolvimento Mat, Sao Carlos, SP, Brazil | - |
dc.identifier.doi | 10.1016/S0584-8547(01)00361-5 | - |
dc.identifier.wos | WOS:000173505300003 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Spectrochimica Acta Part B-atomic Spectroscopy | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.