You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/40064
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBelati, Edmarcio A.-
dc.contributor.authorAlves, Dilson A.-
dc.contributor.authorda Costa, Geraldo R. M.-
dc.date.accessioned2014-05-20T15:30:45Z-
dc.date.accessioned2016-10-25T18:06:21Z-
dc.date.available2014-05-20T15:30:45Z-
dc.date.available2016-10-25T18:06:21Z-
dc.date.issued2008-09-01-
dc.identifierhttp://dx.doi.org/10.1016/j.epsr.2008.01.017-
dc.identifier.citationElectric Power Systems Research. Lausanne: Elsevier B.V. Sa, v. 78, n. 9, p. 1553-1560, 2008.-
dc.identifier.issn0378-7796-
dc.identifier.urihttp://hdl.handle.net/11449/40064-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/40064-
dc.description.abstractThis paper proposes an approach of optimal sensitivity applied in the tertiary loop of the automatic generation control. The approach is based on the theorem of non-linear perturbation. From an optimal operation point obtained by an optimal power flow a new optimal operation point is directly determined after a perturbation, i.e., without the necessity of an iterative process. This new optimal operation point satisfies the constraints of the problem for small perturbation in the loads. The participation factors and the voltage set point of the automatic voltage regulators (AVR) of the generators are determined by the technique of optimal sensitivity, considering the effects of the active power losses minimization and the network constraints. The participation factors and voltage set point of the generators are supplied directly to a computational program of dynamic simulation of the automatic generation control, named by power sensitivity mode. Test results are presented to show the good performance of this approach. (C) 2008 Elsevier B.V. All rights reserved.en
dc.format.extent1553-1560-
dc.language.isoeng-
dc.publisherElsevier B.V. Sa-
dc.sourceWeb of Science-
dc.subjectautomatic generation controlen
dc.subjectload frequency controlen
dc.subjectarea control erroren
dc.subjectoptimal power flowen
dc.subjectactive power loss minimizationen
dc.titleAn approach of optimal sensitivity applied in the tertiary loop of the automatic generation controlen
dc.typeoutro-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionSENAI-
dc.description.affiliationUniv São Paulo, EESC, Dept Elect Engn, BR-05508 São Paulo, Brazil-
dc.description.affiliationUniv São Paulo, UNESP, FEIS, Dept Elect Engn, BR-05508 São Paulo, Brazil-
dc.description.affiliationSENAI, CIMATEC, Salvador, BA, Brazil-
dc.description.affiliationUnespUniv São Paulo, UNESP, FEIS, Dept Elect Engn, BR-05508 São Paulo, Brazil-
dc.identifier.doi10.1016/j.epsr.2008.01.017-
dc.identifier.wosWOS:000257619800009-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofElectric Power Systems Research-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.