You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/40120
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAl Cantara Jr, Naasson P. de-
dc.contributor.authorCosta, Danilo C.-
dc.contributor.authorGuedes, Diego S.-
dc.contributor.authorSartori, Ricardo-
dc.contributor.authorBastos, Paulo S. S.-
dc.contributor.authorEsa, R-
dc.contributor.authorWu, YW-
dc.date.accessioned2014-05-20T15:30:49Z-
dc.date.accessioned2016-10-25T18:06:27Z-
dc.date.available2014-05-20T15:30:49Z-
dc.date.available2016-10-25T18:06:27Z-
dc.date.issued2011-01-01-
dc.identifierhttp://dx.doi.org/10.4028/www.scientific.net/AMR.301-303.597-
dc.identifier.citationAdvanced Measurement and Test, Pts 1-3. Stafa-zurich: Trans Tech Publications Ltd, v. 301-303, p. 597-602, 2011.-
dc.identifier.issn1022-6680-
dc.identifier.urihttp://hdl.handle.net/11449/40120-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/40120-
dc.description.abstractThis paper presents a new non-destructive testing (NDT) for reinforced concrete structures, in order to identify the components of their reinforcement. A time varying electromagnetic field is generated close to the structure by electromagnetic devices specially designed for this purpose. The presence of ferromagnetic materials (the steel bars of the reinforcement) immersed in the concrete disturbs the magnetic field at the surface of the structure. These field alterations are detected by sensors coils placed on the concrete surface. Variations in position and cross section (the size) of steel bars immersed in concrete originate slightly different values for the induced voltages at the coils.. The values for the induced voltages were obtained in laboratory tests, and multi-layer perceptron artificial neural networks with Levemberg-Marquardt training algorithm were used to identify the location and size of the bar. Preliminary results can be considered very good.en
dc.format.extent597-602-
dc.language.isoeng-
dc.publisherTrans Tech Publications Ltd-
dc.sourceWeb of Science-
dc.subjectNon-Destructive Testingen
dc.subjectEddy Current Testingen
dc.subjectConcrete Structuresen
dc.subjectConcrete Re nforcementen
dc.subjectArtificial Neural Networksen
dc.titleA Non-Destructive Testing Based on Electromagnetic Measurements and Neural Networks for the Inspection of Concrete Structuresen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUnesp São Paulo State Univ, BR-17033360 Bauru, SP, Brazil-
dc.description.affiliationUnespUnesp São Paulo State Univ, BR-17033360 Bauru, SP, Brazil-
dc.identifier.doi10.4028/www.scientific.net/AMR.301-303.597-
dc.identifier.wosWOS:000307023300107-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAdvanced Measurement and Test, Pts 1-3-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.