You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/40360
Full metadata record
DC FieldValueLanguage
dc.contributor.authorde Almeida, Eduardo-
dc.contributor.authorMassoni, Paulo Rogerio-
dc.contributor.authorMenegario, Amauri Antonio-
dc.contributor.authorLeite, Laudi Cunha-
dc.contributor.authorDuarte Lanna, Dante Pazzanese-
dc.contributor.authordo Nascimento Filho, Virgilio Franco-
dc.date.accessioned2014-05-20T15:31:08Z-
dc.date.accessioned2016-10-25T18:06:53Z-
dc.date.available2014-05-20T15:31:08Z-
dc.date.available2016-10-25T18:06:53Z-
dc.date.issued2011-11-01-
dc.identifierhttp://dx.doi.org/10.1002/xrs.1361-
dc.identifier.citationX-ray Spectrometry. Hoboken: Wiley-blackwell, v. 40, n. 6, p. 424-426, 2011.-
dc.identifier.issn0049-8246-
dc.identifier.urihttp://hdl.handle.net/11449/40360-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/40360-
dc.description.abstractThis article describes a comparison of conventional energy-dispersive X-ray fluorescence (EDXRF) and synchrotron radiation total-reflection X-ray fluorescence (SRTXRF) for Co determination in ruminal fluid from Holstein cow. This element is used as marker for animal nutrition studies. For EDXRF, 200 mu l of the sample were dried on 6.35 mu m Mylar filmat 60 degrees C. The excitation was carried out using an X-ray tube with Mo target and Zr filter operated at 30 kV/ 20 mA. For SRTXRF, 10 mu l of the samplewere pipetted on a Lucite carrier and dried at 60 degrees C. In both the techniques, Ga was used as internal standard and the acquisition time was 200 s. The trueness of both techniques was evaluated through the standard addition method, the recoveries obtained by SRTXRF and EDXRF were 76 and 99%, and the limits of detection, 13 and 240 mu g l(-1), respectively. Copyright (C) 2011 John Wiley & Sons, Ltd.en
dc.description.sponsorshipLaboratório Nacional de Luz Síncrotron (LNLS)-
dc.format.extent424-426-
dc.language.isoeng-
dc.publisherWiley-Blackwell-
dc.sourceWeb of Science-
dc.titleDetermination of cobalt marker in cow ruminal fluid by EDXRF and SRTXRFen
dc.typeoutro-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv São Paulo, CENA, LIN, BR-13400970 Piracicaba, SP, Brazil-
dc.description.affiliationUniv Estadual Paulista Julio de Mesquita Filho UN, CEA, BR-13506900 Rio Claro, SP, Brazil-
dc.description.affiliationUniv São Paulo, Escola Super Agr Luiz de Queiroz ESALQ, Dept Zootecnia, LNCA, BR-13418970 Piracicaba, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista Julio de Mesquita Filho UN, CEA, BR-13506900 Rio Claro, SP, Brazil-
dc.description.sponsorshipIdLNLS - Brazilian Synchrotron Light Laboratory: D09-XRF-6648-
dc.identifier.doi10.1002/xrs.1361-
dc.identifier.wosWOS:000297053400005-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofX-Ray Spectrometry-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.