Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/41006
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Oliveira, M. E. | - |
dc.contributor.author | Padilha-Feltrin, A. | - |
dc.date.accessioned | 2014-05-20T15:32:00Z | - |
dc.date.accessioned | 2016-10-25T18:08:03Z | - |
dc.date.available | 2014-05-20T15:32:00Z | - |
dc.date.available | 2016-10-25T18:08:03Z | - |
dc.date.issued | 2009-10-01 | - |
dc.identifier | http://dx.doi.org/10.1109/TPWRD.2009.2014266 | - |
dc.identifier.citation | IEEE Transactions on Power Delivery. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc, v. 24, n. 4, p. 2117-2124, 2009. | - |
dc.identifier.issn | 0885-8977 | - |
dc.identifier.uri | http://hdl.handle.net/11449/41006 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/41006 | - |
dc.description.abstract | A methodology, which can be classified as Top-Down, aimed at computing technical losses in distribution systems is proposed. It can be applied to either evaluate part of the network or to analyze the whole distribution system. This methodology basically requires the load curve of the studied feeder or substation, and, depending on the analyzed segment, some complementary data. Thus, the contribution of this proposal becomes significant when compared to other methodologies that commonly require large and updated databases, often not available. The proposed technique was applied to two real Brazilian distribution systems. Results, compared with measured data, show the effectiveness of the methodology in computing losses by segments and for the whole circuit. | en |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | - |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | - |
dc.format.extent | 2117-2124 | - |
dc.language.iso | eng | - |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | - |
dc.source | Web of Science | - |
dc.subject | Allocation factor | en |
dc.subject | energy losses | en |
dc.subject | load curve | en |
dc.subject | loss factor | en |
dc.title | A Top-Down Approach for Distribution Loss Evaluation | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | UNESP, Ilha Solteira, SP, Brazil | - |
dc.description.affiliationUnesp | UNESP, Ilha Solteira, SP, Brazil | - |
dc.description.sponsorshipId | FAPESP: 04/04400-4 | - |
dc.description.sponsorshipId | FAPESP: 07/07041-3 | - |
dc.description.sponsorshipId | CNPq: 308010/2006-0 | - |
dc.identifier.doi | 10.1109/TPWRD.2009.2014266 | - |
dc.identifier.wos | WOS:000270139900041 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | IEEE Transactions on Power Delivery | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.