You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/41058
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSilva, Barbara V. M.-
dc.contributor.authorCavalcanti, Igor T.-
dc.contributor.authorMattos, Alessandra B.-
dc.contributor.authorMoura, Patricia-
dc.contributor.authorSotomayor, Maria Del Pilar Taboada-
dc.contributor.authorDutra, Rosa F.-
dc.date.accessioned2014-05-20T15:32:04Z-
dc.date.accessioned2016-10-25T18:08:09Z-
dc.date.available2014-05-20T15:32:04Z-
dc.date.available2016-10-25T18:08:09Z-
dc.date.issued2010-11-15-
dc.identifierhttp://dx.doi.org/10.1016/j.bios.2010.08.051-
dc.identifier.citationBiosensors & Bioelectronics. Oxford: Elsevier Advanced Technology, v. 26, n. 3, p. 1062-1067, 2010.-
dc.identifier.issn0956-5663-
dc.identifier.urihttp://hdl.handle.net/11449/41058-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/41058-
dc.description.abstractScreen-printed electrodes (SPE) have been widely used in the design of disposable sensors bringing advances in the use of electrochemical immunosensors for in field-clinical analysis. In this work, streptavidin polystyrene microspheres were incorporated to the electrode surface of SPEs in order to increase the analytical response of the cardiac troponin T (cTnT), a specific biomarker for the acute myocardial infarction diagnosis. The precise calculation of the stoichiometric streptavidin-biotin ratio [1:4]allowed the increase of sensitivity and stability of the immunosensor response to the cTnT analyte. The surface of the immunosensor was characterized by scanning electron microscopy and cyclic voltammetry. It was observed that the use of streptavidin microspheres significantly increased the analytical sensitivity of the electrode in 8.5 times, showing a curve with a linear response range between 0.1 and 10 ng mL(-1) of cTnT and a detection limit of 0.2 ng mL(-1). The proposed SPE showed ease preparation and high sensitivity allowing the detection of cTnT in the range of clinical levels. The new device coupled with a portable electrochemical analyzer shows great promise for point-of-care quantitative testing of necrosis cardiac proteins. (C) 2010 Elsevier B.V. All rights reserved.en
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.description.sponsorshipFundação de Amparo à Ciência e Tecnologia do Estado de Pernambuco (FACEPE)-
dc.format.extent1062-1067-
dc.language.isoeng-
dc.publisherElsevier Advanced Technology-
dc.sourceWeb of Science-
dc.subjectImmunosensoren
dc.subjectScreen-printed electrodeen
dc.subjectMyocardial infarctionen
dc.subjectTroponin Ten
dc.titleDisposable immunosensor for human cardiac troponin T based on streptavidin-microsphere modified screen-printed electrodeen
dc.typeoutro-
dc.contributor.institutionUniv Pernambuco-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Pernambuco, Pronto Socorro Cardiol Pernambuco PROCAPE, Lab Pesquisa Diagnost LAPED, BR-50100130 Recife, PE, Brazil-
dc.description.affiliationUniv Estadual Paulista, Inst Quim Araraquara, São Paulo, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Inst Quim Araraquara, São Paulo, Brazil-
dc.description.sponsorshipIdCNPq: 554793/2006-7-
dc.description.sponsorshipIdCNPq: 550755/2007-1-
dc.identifier.doi10.1016/j.bios.2010.08.051-
dc.identifier.wosWOS:000283813600017-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofBiosensors & Bioelectronics-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.