You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/41278
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMenegario, Amauri A.-
dc.contributor.authorSmichowski, Patricia-
dc.contributor.authorTonello, Paulo S.-
dc.contributor.authorPolla, Griselda-
dc.contributor.authorOliveira, Eliane P.-
dc.contributor.authorSantelli, Ricardo E.-
dc.date.accessioned2014-05-20T15:32:21Z-
dc.date.accessioned2016-10-25T18:08:33Z-
dc.date.available2014-05-20T15:32:21Z-
dc.date.available2016-10-25T18:08:33Z-
dc.date.issued2008-09-12-
dc.identifierhttp://dx.doi.org/10.1016/j.aca.2008.07.029-
dc.identifier.citationAnalytica Chimica Acta. Amsterdam: Elsevier B.V., v. 625, n. 2, p. 131-136, 2008.-
dc.identifier.issn0003-2670-
dc.identifier.urihttp://hdl.handle.net/11449/41278-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/41278-
dc.description.abstractL-proline was immobilized on controlled pore glass to study the ability of this material for the separation and preconcentration of Sb(III) and Sb(V). The substrate was packed in a minicolumn and incorporated in a flow injection system. The effluents of the on-line solid phase extraction (before and after elution) were directly coupled to the hydride generation inductively coupled plasma optical emission spectrometry system. The effect of pH, sample (and eluent) volume, flow rates of sample loading and elution on separation of Sb(III) e Sb(V) were evaluated. Our experiments demonstrated that Sb(V) was not retained and it was selectively determined during the loading step, while retained Sb(III) was determined afterelution. The proposed system was also used for the selective preconcentration of Sb(III). In this case, a preconcentration factor of 11 and a limit of detection of 90 ng L-1 for Sb(III) were achieved when 8 mL of sample were loaded into the column. The speciation analysis of inorganic Sb in river water and effluent samples was performed using the proposed method. The values obtained for total Sb (obtained by sum of Sb(III) and Sb(V)) were in good agreement with expected values. Recoveries of Sb(III) and Sb(V) in the river water Standard Reference Material 1640 (from National Institute of Standard and Technology) and spiked river waters were between 83 and 111%. (C) 2008 Elsevier B.V. All rights reserved.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extent131-136-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectantimonyen
dc.subjectL-prolineen
dc.subjectspeciation analysisen
dc.subjectcontrolled pore glassen
dc.subjecthydride generationen
dc.titleOn-line redox speciation analysis of antimony using L-proline immobilized on controlled pore glass and hydride generation inductively coupled plasma optical emission spectrometry for detectionen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionComis Nacl Energia Atom Gerencia Quim-
dc.contributor.institutionConsejo Nacl Invest Cient & Tecn-
dc.contributor.institutionComis Nacl Energia Atom Gerencia Invest & Aplicac-
dc.contributor.institutionUniversidade Federal Fluminense (UFF)-
dc.description.affiliationUniv Estadual Paulista, Ctr Estudos Ambientais, BR-13506900 Rio Claro, SP, Brazil-
dc.description.affiliationComis Nacl Energia Atom Gerencia Quim, RA-1499 San Martin, Argentina-
dc.description.affiliationConsejo Nacl Invest Cient & Tecn, RA-1033 Buenos Aires, DF, Argentina-
dc.description.affiliationUniv Estadual Paulista, Programa Posgrad Quim IQ, BR-14800900 Araraquara, SP, Brazil-
dc.description.affiliationComis Nacl Energia Atom Gerencia Invest & Aplicac, RA-1499 San Martin, Argentina-
dc.description.affiliationUniv Fed Fluminense, Dept Geoquim, BR-24020150 Niteroi, RJ, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Ctr Estudos Ambientais, BR-13506900 Rio Claro, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Programa Posgrad Quim IQ, BR-14800900 Araraquara, SP, Brazil-
dc.identifier.doi10.1016/j.aca.2008.07.029-
dc.identifier.wosWOS:000259480000002-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAnalytica Chimica Acta-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.