You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/41385
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVidal, Isabelle Goncalves-
dc.contributor.authorTescarollo Dias, Iara Lucia-
dc.contributor.authorde Oliveira Neto, Graciliano-
dc.contributor.authorde Vasconcellos Lanza, Marcos Roberto-
dc.contributor.authorTaboada Sotomayor, Maria Del Pilar-
dc.date.accessioned2014-05-20T15:32:30Z-
dc.date.accessioned2016-10-25T18:08:45Z-
dc.date.available2014-05-20T15:32:30Z-
dc.date.available2016-10-25T18:08:45Z-
dc.date.issued2009-01-01-
dc.identifierhttp://dx.doi.org/10.1080/00032710802507927-
dc.identifier.citationAnalytical Letters. Philadelphia: Taylor & Francis Inc, v. 42, n. 2, p. 352-365, 2009.-
dc.identifier.issn0003-2719-
dc.identifier.urihttp://hdl.handle.net/11449/41385-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/41385-
dc.description.abstractA rapid and effective method for carbamide peroxide (CP) quantification in pharmaceuticals is proposed. The reagentless biosensor was prepared by using lyophilized turnip extract as horseradish peroxidase (HRP) enzyme source. The biosensor presented the best performance. The measurements were carried out in 0.1mol L-1 Pipes buffer (pH 6.0). At-100mV vs. Ag|AgCl, a linear response range from 3.0 to 25.0mmol L-1 was obtained. The quantification and detection limits were 1.2 and 0.4mmol L-1, respectively, and the response time was 0.5s. The biosensor repeatability, storage, and lifetime were excellent, allowing a satisfactory CP quantification in real pharmaceutical samples, when compared with those obtained by the official method.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extent352-365-
dc.language.isoeng-
dc.publisherTaylor & Francis Inc-
dc.sourceWeb of Science-
dc.subjectAmperometric biosensoren
dc.subjectbrassica napus Len
dc.subjectcarbamide peroxideen
dc.subjectHRPen
dc.subjectlyophilization procedureen
dc.titleCarbamide Peroxide Determination in Tooth Whitening Using a Reagentless HRP-Biosensoren
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniv Sao Francisco-
dc.contributor.institutionCity Dept Educ-
dc.description.affiliationSão Paulo State Univ, Inst Chem, BR-14800900 Araraquara, SP, Brazil-
dc.description.affiliationUniv Sao Francisco, BR-12900000 Braganca Paulista, SP, Brazil-
dc.description.affiliationCity Dept Educ, Campinas, SP, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Inst Chem, BR-14800900 Araraquara, SP, Brazil-
dc.description.sponsorshipIdCNPq: 470025/2006-9-
dc.identifier.doi10.1080/00032710802507927-
dc.identifier.wosWOS:000263553400013-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAnalytical Letters-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.