You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/41635
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMoreira, Luiz Fernando-
dc.contributor.authorde Vasconcelos Lanza, Marcos Roberto-
dc.contributor.authorTanaka, Auro Atsushi-
dc.contributor.authorTaboada Sotomayor, Maria Del Pilar-
dc.date.accessioned2014-05-20T15:32:50Z-
dc.date.accessioned2016-10-25T18:09:12Z-
dc.date.available2014-05-20T15:32:50Z-
dc.date.available2016-10-25T18:09:12Z-
dc.date.issued2009-01-01-
dc.identifierhttp://dx.doi.org/10.1039/b902273b-
dc.identifier.citationAnalyst. Cambridge: Royal Soc Chemistry, v. 134, n. 7, p. 1453-1461, 2009.-
dc.identifier.issn0003-2654-
dc.identifier.urihttp://hdl.handle.net/11449/41635-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/41635-
dc.description.abstractThis work describes the construction and application of two amperometric sensors for sensitive UV-filter determination. The sensors were prepared using stainless steel electrodes in which polyaniline (PANI) was electrochemically polymerized in the presence of nickel (NiPcTS) or iron (FePcTS) tetrasulfonated phthalocyanines. The sensor surface characterizations were carried out using atomic force microscopy (AFM). The PANI/NiPcTS sensor was selective for the chemical UV-filter p-aminobenzoic acid (PABA) and the PANI/FePcTS sensor was selective for octyldimethyl-PABA (ODP), both in a mixture of tetrahydrofuran (THF) and 0.1 mol L(-1) H(2)SO(4) at a volume ratio of 30 : 70, and with an applied potential of 0.0 mV vs. Ag vertical bar AgCl. A detailed investigation of the selectivity was carried out for both sensors, in order to determine their responses for ten different UV filters. Finally, each sensor was successfully applied to PABA or ODP quantification in sunscreen formulations and water from swimming pools.en
dc.format.extent1453-1461-
dc.language.isoeng-
dc.publisherRoyal Soc Chemistry-
dc.sourceWeb of Science-
dc.titleSelective UV-filter detection with sensors based on stainless steel electrodes modified with polyaniline doped with metal tetrasulfonated phthalocyanine filmsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniv Sao Francisco-
dc.contributor.institutionUniversidade Federal do Maranhão (UFMA)-
dc.description.affiliationUniv Estadual Paulista, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUniv Sao Francisco, BR-12900000 Braganca Paulista, SP, Brazil-
dc.description.affiliationUniversidade Federal do Maranhão (UFMA), Ctr Ciencias Exatas & Tecnol, Sao Luis, MA, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.doi10.1039/b902273b-
dc.identifier.wosWOS:000267499800028-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAnalyst-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.